The pump is equipped with a power supply board that regulates the power absorbed as a function of the
operating pressure (excluding the BASIC series). The following table shows the technical features of the
eOne series and the corresponding flow curves:
Type
Flow at Max Pressure
Pressure
Setting
Electric
Power
Current
Weight
L/h
mL/min
mL/
stroke
Max [bar]
[imp/1’]
Power supply
[W]
MAX [A]
[kg]
0110
1 (0.26)
16,66
0,09
10 (145)
0
–
180
100 -250 V
50-60 Hz
19
1.4
3.0
0216
2 (0.53)
50,00
0,11
16 (232)
0
–
300
21
1.4
3.5
0420
4 (1.06)
83,33
0,22
20 (290)
0
–
300
21
1.4
3.0
0607
6 (1.59)
83,33
0,33
7 (101)
0
–
300
28
2.0
4.5
0710
7 (1.84)
133,33
0,39
10 (145)
0
–
300
26
1.8
3.5
1012
10 (2.64) 166,66
0,56
12 (174)
0
–
300
36
1.8
4.5
1505
15 (3.96) 250,00
0,83
5 (72)
0
–
300
26
1.8
3.5
2007
20 (5.26) 333,33
1,11
7 (101)
0
–
300
32
1.9
4.7
3005
30 (7.92) 500,00
1,66
5 (72)
0
–
300
32
1.9
4.7
0210(*) 2 (0.53)
33,33
0,18
10 (145)
0
–
180
36
1.6
3.0
0507(*) 5 (1.32)
83,33
0,46
7 (101)
0-180
36
1.6
3.0
(*) BASIC model only
The values shown are with a tolerance of + / - 5%, and relate to a series of tests carried out on similar
equipment with water at a temperature of 20 ° C.
Pump
Head
Membrane
Seals
Valves
Connections
Pipes
Pump
Casing
PVDF
PTFE
TFE/P
CERAMIC
TFE/P
PVDF
PE / PVC
PP