Step 8(d): No empty breaker
and three 200A CTs
Uncommon in N. American homes
Common in N. American commercial systems
Secure the
White
wire from the wire harness
to the neutral bus bar. Turn off three
vertically adjacent (stacked) 15A single pole
breakers and remove their wires. Connect
one of the breaker wires to the
Black
harness wire and an extra wire with a wire
nut. Next, connect the second breaker wire
to the
Red
harness wire and an extra wire
with a wire nut. Next, connect the third
breaker wire to the
Blue
harness wire and an
extra wire with a wire nut. Then secure each
of the extra wires to the three breaker poles.
Summary of Contents for Vue