Page 37
Series 2000/3000 IDU User’s Manual
Revision P4
!CFG: Filter patterns with same subnet linked
to different IPSEC servers (<FP1#> and
<FP2#>)
Where <FP#> is a filter pattern number.
!CFG: Enabling IPSEC for OAM queue is not
allowed (<SQ#>)
Where <SQ#> is a SAT queue number.
!CFG: SAT queue linked to invalid IPSEC
server (<SQ#>)
!CFG: Filter pattern linked to invalid SAT
queue (<FP#>)
!DWNL: Cannot find specified SIT image
(<sitimagepath>).
!DWNL: Current SIT image was not vali-
dated, toggled to Alternate SIT image.
This usually happens when the new software
image was not validated after 10 minutes.
!RLINK: Signalling Data Invalid
(<tablename>)
Where <tablename> is the name of the
signalling with invalid data.
!RLINK: Center Frequency Out of Range
The transmit frequency must be within
range of the IDU’s transmit frequency
plus the ODU Tx mixing Frequency (See
IDU Installation Manual
!SYNC: Start of Frame Timeout
Usually a temporary error.
!SYNC: PCR Missing
!SYNC: PCR Reload
!SYNC: PCR Absence Detected
!SYNC: Missing CMT
The IDU does not receive a response to its
SYNC burst sent to the Hub.
!SYNC: Timing Correction Outside Threshold
!FLINK: Signalling Table Format Invalid
(<tablename>)
Where <tablename> is the name of the
signalling with invalid data.
!FLINK: L-Band Frequency Out of Range
This is the configured frequency minus
the ODU Rx mixing frequency. It must be
within the IDU’s L-Band frequency range
!FLINK: Symbol Rate Out of Range
!RADIUS: User Authentication Failed
(<username>)
Where <username> is the name of the
user who failed authentication.
!IPSEC: SIT Security Association Negotiation
Failed (<mode>)
Where <mode> is either main or quick
mode.
Table 13: