Responsible  handling  of  the  Easy  Motion Skin

®

  is  a condition  of  suc-

cessful  and  safe  use.  Careful  studying  of  this  instruction  manual  is  a 
prerequisite  for  safe  operation  of  the  Easy  Motion  Skin

®

.  Should  you 

still  have  questions,  or  are  unsure  whether  the  Easy  Motion  Skin

®

  is 

suitable for you, please contact the manufacturer. 

The  manufacturer  advises  purchasing  the  Easy  Motion  Skin

®

  from  a 

distribution partner trained by the manufacturer.   

 

The  instruction  manual  accompanying  the  device  as  well  as  the  pro-
gramme description contain information for safe handling of the Easy 
Motion  Skin

®

  and must  be  carefully  read  and  understood  by the  user 

before using the Easy Motion Skin

®

.  

The instruction manual is a component on the Easy Motion Skin

®

. The 

safety instructions contained in the instruction manual complement the 
guidelines on the area of application of the Easy Motion Skin 

®

. Observ-

ing  the  safety instructions  indicated  in the  instruction manual  and the 
instructions relating to handling the Easy Motion Skin

®

 are a condition 

of safe training. 

 

Delivery of the Easy Motion Skin

®

 includes: 

 

  Powerbox 

  Powerbox power supply unit 

  MotionSkin (Training body) 

– optional sizes e.g. 1, 2, 3, 4 

  Instruction manual 

  Tightening straps 

 

General  
Information 

Instruction man-
ual 

Scope of deliv-
ery 

Summary of Contents for Easy Motion Skin

Page 1: ...EN Instruction manual Easy Motion Skin Version 2 0 05 2020 ...

Page 2: ......

Page 3: ... manufacturer accepts no liability for damage to persons animals or property or to the product itself which arises from improper use fail ure to observe or inadequate observation of the safety criteria con tained in these instructions or any alterations to the Easy Motion Skin or the use of unsuitable replacement parts non original parts Protection notice Copyright in accordance with DIN ISO 16016...

Page 4: ...in is a highly efficient training system consisting of the MotionSkin with Powerbox which communicates with an tablet smartphone via Bluetooth Low frequency electrical impulses electromyostimulation are controlled using an Easy Motion Skin application thus stimulating practically the entire musculature The manufacturer bears sole responsibility for publication of this decla ration of conformity Th...

Page 5: ...y a differentiation between four warning levels identified by corresponding signal words and colouring DANGER immediate threat to life WARNING possible threat to life or injury CAUTION possible risk of injury ATTENTION possible damage to property INFOR MATION no danger no damage to property At appropriate points in the text of this instruction manual safety sym bols are used which require particul...

Page 6: ...ion 9 Charging the Powerbox 10 Setting up the MotionSkin 11 Connecting the Powerbox to the MotionSkin 11 Performing training 12 Switch on the Powerbox 16 Using tablet smartphone 16 Using the Easy Motion Skin app 16 Condensation 17 Spare parts 17 MotionSkin care and cleaning instructions 18 Powerbox care and cleaning instructions 20 Disposal protection of the environment 21 Technical data 22 ...

Page 7: ...formation for safe handling of the Easy Motion Skin and must be carefully read and understood by the user before using the Easy Motion Skin The instruction manual is a component on the Easy Motion Skin The safety instructions contained in the instruction manual complement the guidelines on the area of application of the Easy Motion Skin Observ ing the safety instructions indicated in the instructi...

Page 8: ...inally developed for therapeutic and rehabilitation purposes the Easy Motion Skin uses this technology for high efficiency training re sults in short periods INFORMATION The Easy Motion Skin is an EMS training device exclusively for people To avoid accidents and to guarantee full func tionality of the Easy Motion Skin a well fit ting MotionSkin of the correct size must be used Even when used appro...

Page 9: ...possible applications of the Easy Motion Skin The Easy Motion Skin must only be used as an EMS training device for people in a dry environment and it is not a medical device Please consider any contraindications which may oppose use Ensure the MotionSkin fits properly Only train while the power supply unit is not connected to the Powerbox Always start training with low intensity and increase slowl...

Page 10: ...hreat to life caused by cardiac arrythmia Cardiac arrythmia can lead to loss of con sciousness There is a residual risk that EMS training can trigger cardiac arrythmia which can be fatal consequences if not treated Immediate action in the event of a loss of consciousness 1 Disconnect the Powerbox completely from the MotionSkin 2 Call the emergency services 3 Carry out resuscitation measures 4 Use ...

Page 11: ...verity NYHA IV Severe arterial circulatory disorders e g forefoot gangrene in dia betics Cancer Haemophilia Pregnancy Severe neurological illness e g multiple sclerosis amyotrophic lat eral sclerosis Parkinson s disease epilepsy spastic spinal paraly sis Advanced arteriosclerosis Abdominal wall or inguinal hernia Acute febrile bacterial or viral illness Acute bleeding Extreme blood pressure Thromb...

Page 12: ...one of the contraindications listed are present Do not use the Easy Motion Skin if there is any doubt about the presence of a con traindication The Easy Motion Skin must absolutely not be used with persons fitted with a pacemaker or other active medical im plants If in doubt or where medication is taken please consult a doctor before use ...

Page 13: ... use Only use in dry surroundings Only connect the power supply unit to a mains supply of 100 230 V 47 63 Hz and only use power supply units supplied by the manufacturer Always inform the manufacturer in the event of faults or damage CAUTION Risk of injury form damage to cables and connectors There is a risk of damage to property and personal injury due to damage to connectors or cables Do not tra...

Page 14: ...heat open flames and corrosive liquids Do not punch break or burn Avoid vapour contact with the skin eyes and do not inhale To extinguish a fire conventional extin guishing materials may be used such as ABC powder CO2 extinguisher or water In case of contact with released electro lytes gases or fire byproducts by the eyes 1 rinse thoroughly with water for at least 15 minutes and consult a doctor i...

Page 15: ...lified Without adequate knowledge of use han dling the Easy Motion Skin may lead to dan gerous situations In extreme cases these could be fatal Before use every user must have read and understood this instruction manual Anyone under 16 years of age may not train with the Easy Motion Skin INFORMATION Repairs and service Repairs maintenance and service may only be carried out by EMS GmbH User qualif...

Page 16: ...e Powerbox is not connected to a Motion Skin 2 Connect the Powerbox to a socket using the power sup ply unit supplied The following status is displayed when the Powerbox is turned on or during charging Red light flashes quickly Low battery Red light flashes Battery charging Red light is on Battery is charged Rechargeable batteries have a limited number of charging cycles and must be replaced over ...

Page 17: ...n until the connection is re established properly Your retailer will advise you on selecting the correct size If in doubt the fit of the MotionSkin can also be optimised using the tension straps sup plied Overexpansion of the MotionSkin must be avoided as it may lead to damage Connect the Powerbox with the MotionSkin The push buttons on the MotionSkin should be con nected with their counterparts p...

Page 18: ... stimulated must be tensed naturally and deliberately prior to each stimulation phase This level of muscle tension is to be main tained during the course of a stimulation phase Training intensity Physical exertion during training must be higher than the normal level of exertion when not training However loss of breath or fatigue should not arise during training Ability to talk serves as a benchmar...

Page 19: ...th a significant level of ex ertion in doing so you must take into ac count individual pain thresholds and load ca pacity When training with the Easy Motion Skin special attention must be paid to voluntarily contracting the muscle groups while exhaling simul taneously in a controlled and consistent manner This particularly ap plies to the stimulation phase during 85Hz training The effectiveness of...

Page 20: ...d metabolism Designing a training regime Each training unit should consist of three training phases warming up training and cooling down phases During the warming up phase the body temperature and supply of ox ygen should be slowly increased This can normally be achieved by us ing gymnastic exercises over a period of five to ten minutes The training phase then follows Training exertion should be k...

Page 21: ...ainer may be sought in order to ensure optimal training and results WARNING Overexertion through EMS training EMS Training is an especially effective form of training and can lead to overexertion in in dividual cases particularly if the training in tensity is too high Should you experience pain headaches nausea circulatory problems persistent fa tigue or other health changes following EMS training...

Page 22: ...ons supplied separately in the manufacturer s original packaging Start the Easy MotionSkin app by tapping on the cor responding icon This is located on the home screen of your tablet smartphone Download the app for free from the Apple App Store or Google Play Store For more detailed instructions see the tablet smartphone manufacturer documentation INFORMATION Programme description Please see the E...

Page 23: ...rts can alter the functional ity of the Easy Motion Skin Non original parts can damage the Easy Motion Skin PLEASE NOTE Damage from condensation Condensation can arise through changes in the air humidity and temperature Condensa tion in the Easy Motion Skin components can lead to a fault or damage Do not use the Easy Motion Skin if con densation can be seen Acclimatise the device after a change of...

Page 24: ...les which may not be ironed To identify textiles which may not be dry cleaned Washing Easy Motion Skin training suits are suitable for machine washing gen tle wash at 30 C EMS GmbH recommends hand washing Wash the MotionSkin with the zip closed and electrodes pointing inwards Detergents All mild detergents which do not contain chlorine bleach and fabric softener are suitable EMS GmbH recommends e ...

Page 25: ...TION Residual dampness after spinning The MotionSkin can be used immediately af ter spin drying It may still feel slightly damp which is not an issue when in use and actu ally enhances the functionality of the elec trodes Drying The MotionSkin should be air dried hanging on a hanger with the elec trodes turned inside out PLEASE NOTE Damage caused by drying The MotionSkin should be air dried If dri...

Page 26: ...the power supply Keep the device away from liquids and en sure that moisture does not penetrate the openings Do not directly spray cleaning agents onto the device Do not use any sprays solvents or abrasives while cleaning Powerbox care and cleaning in structions ...

Page 27: ... Improper disposal can endanger the environ ment Batteries should not be disposed of in domestic waste Environmentally responsible and accurate disposal should be carried out in accord ance with local regulations for the disposal of electrical components and electrical waste Recycle appropriate elements such as plastics or metal Batteries should be brought to a local recy cling site for environmen...

Page 28: ...pply Built in Li Polymer rechargeable battery pack Accumulator 3 7 V 1300 mAh Dimensions 66 mm x 24 mm x 118 mm Weight 140 g Network connec tion Input AC 100 V 240 V 50 Hz 60 Hz tablet smartphone Design in accordance with manufacturer s infor mation Technical data ...

Page 29: ...23 Notes ...

Page 30: ...EMS GmbH Windscheidstr 21 23 04277 Leipzig www easymotionskin com info easymotionskin com ...