background image

1 Pre installation

2 Components

3

Part no           Product description

EC-41-0200

EMS Wireless Zone Interface Module

Zone Interface Module

Installation Guide

IDENT REV DATE

FC-610-001 EN300 200-2

0905

!

20K

4K7

C

N/O

20K  = Red/Bl

4k7 = Yellow 

EOL Resistor

Configuration

ANTENNA

2

1

4 Remove cable entry points

5 Fix 

to the wall

 

Drill the cable entry 

points as necessary.

Cable glands should 

be used.

DO NOT leave excess 

cable in the device.

ON

INPUT 1

INPUT 2

 

EXPAN1

EXPAN2

OUTPUT  2

OUTPUT  1

IP-    IP+ IP-    IP+

3VDC SET RS

T

N/O COM

N/C

3VDC

SET RST

N/O COM

N/C

DO NOT use

=

Available 

cable entry 

points

=

3 Mounting location guidelines

Ensure the ZIM is not installed 

within 2 m of the control panel  

or any other wireless or 

electrical equipment.

Ensure the ZIM is not installed 

within 0.6 m of any metal work.

Ensure the ZIM is not installed 

within 0.6 m of the WZM.

WIRELESS ZONE INTERFACE MODULE

WZM

ZIM

0.6 m 

Existing 

control panel

WZM

ZIM

0.6 m 

POWER

FAULT

WIRELESS ZONE MONITOR

2 m

WIRELESS ZONE INTERFACE MODULE

WIRELESS ZONE INTERFACE MODULE

POWER

FAULT

WIRELESS ZONE MONITOR

Existing 

control panel

FIRE

Fire Alarm Control

FIRE

Fire Alarm Control

!

Installation must conform to applicable local installation 

codes and should only be installed by a fully trained 

competent person. 

Ensure that the device is installed as per the site survey.

The use of a non-metallic spacer should be considered if 

mounting the device on to a metal surface.

DO NOT press the log on button on a pre-programmed 

device, as this will cause communication with the control 

panel to be lost. Should this happen, delete the device from 

the system and add it back on.

This device contains electronics that may be susceptible to 

damage from Electrostatic Discharge (ESD). Take appropriate 

precautions when handling electronic boards.

4x lid fixing screws

Front lid

Back box

1

2

3

For  optimum wireless 

performance,  the 

following must be 

observed:

Use all four circled 

fixing positions to 

ensure a firm fixing.

Use suitable fasteners 

and fixings.

               ANTENNA

KEEP CABLES AWAY FROM THIS AREA

LOGON

OUTPUT 

2

OUTPUT  1

3VDC SET RST

INPUT 1 INPUT 2 

LED

ENABLE

POWER

INPUT 

INPUT 

FAULT

CLOSED

0

1

1

64

F-SAFE

N/O COM N/C

IP-    IP+ IP-    IP+

3VDC SET RST

N/O COM N/C

EXPAN1

EXPAN2

RELA

Y ON

RELA

Y ON

2

4

8

16

32

ON

1      2       3      4       5      6       7     8

012ABC

    

Fixing position 

location within 

cavity

©2021 EMS Ltd. All rights reserved.                                                                     Page 1 of 2 

TSD142-99  Iss 6 15/12/2021   AJM