background image

Preliminary Document 

Confidential 

EMS Wireless 

Link

2

Cell

TM

-19 

Manual 

12

 

 

Getting Started

:    

 
Unpack all of the boxes and insure all of the material is included for your installation 
requirements and undamaged in shipment.  
 

Quantity 

Part Description 

Link

2

Cell™  SOHO Signal Enhancer 

Loctite Thread locker  

Power Converter 

Mounting Base 

Mounting Posts 

Wall Anchors 

Mounting Screws 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Figure 1 

Package Contents 

 
 
 
 

Link2Cell Repeater

Power Converter

Mounting Base

Mounting Posts (2)

Wall Anchors (4)

Mounting Screws (4)

LOCTITE Threadlocker

Summary of Contents for Link2Cell-19

Page 1: ... Buford GA 30518 USA Voice 770 831 8048 Fax 770 831 8598 Type Acceptance Test Report Multimode PCS Repeater FCC Rule Parts 2 15 24 ACS Report Number 03 0089 24TA Manufacturer EMS Wireless Model Link2Cell Installation Guide ...

Page 2: ...Link2Cell 19 SOHO Signal Enhancer Small Office Home Office SIGNAL ENHANCER OPERATOR S MANUAL 2850 Colonnades Court NW Norcross GA 30071 Phone 770 582 0555 Fax 770 729 0075 Email www emswireless com ...

Page 3: ... to date Users are cautioned however that EMS Wireless reserves the right to make changes without notice and shall not be responsible for any damages including consequential caused by reliance on the material presented including but not limited to typographical arithmetical or listing errors Copyright Information EMS Wireless EMS Wireless Norcross Georgia ...

Page 4: ...the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help In accordance with FCC regulations regarding human exposure to radiofrequency energy this device shall be installed such that a minimum separation d...

Page 5: ...ss assumes no liability for the customer s failure to comply with these precautions WARNING WARNING Calls attention to a procedure or practice which if ignored may result in damage to the system or system component Do not perform any procedure preceded by a WARNING until described conditions are fully understood and met If You Need Help If you need additional copies of this manual or have question...

Page 6: ...are covered by the following warranties 1 General Warranty EMS Wireless warrants to the original purchaser all standard products sold by EMS Wireless to be free of defects in material and workmanship for the duration of the warranty period of one 1 year from date of shipment from EMS Wireless During the warranty period EMS Wireless obligation at our option is limited to repair or replacement of an...

Page 7: ...ny kind including negligence for any loss or damage arising from connected with or resulting from the purchase order contract or quotation or from the performance or breach thereof or from the design manufacture sale delivery installation inspection operation or use of any equipment covered by or furnished under this contract shall in no case exceed the purchase price of the device which gives ris...

Page 8: ...e Link2Cell 19 1 Use ESD precautions when dealing with the modules within the Link2Cell 19 so that units are not damaged 2 Opening the unit voids warranty 3 Disconnecting any component within the Link2Cell 19 when powered can damage or destroy the equipment and will void the warranty ...

Page 9: ...the gain as required for proper system performance For example when CDMA protocol system is being amplified there could be an error in set up initially resulting from only pilot sync and paging Walsh codes being present on the RF carrier The Link2Cell 19 will reduce the system gain until no signal is received that will exceed the output power setting This prevents the Link2Cell 19 from setting up ...

Page 10: ... Flashing Indication System Initialization Auto Set Up Red Flashing Indication Warning fault condition Unit will reset gain to stable operation Solid Indication Alarm Contact your Service Provider Amber Flashing Indication No RF Signal Detected 90 dBm Solid Indication Weak RF Signal 85 dBm Initial System Automatic Set Up First 2 3 minutes of DC power being applied Indicator State Description Green...

Page 11: ...t voltage of 115 VAC Donor Server Antenna Internal donor and server antenna are each 13 dB nominal gain The donor antenna must be orientated to point in the direction of the Service Providers cell site location Beam width of the antennas is approximately 60 degrees wide so it is necessary for the antenna to point toward the cell site The indicators will provide a reference of the strongest RF powe...

Page 12: ...l Office Home Office signal enhancer to provide additional coverage and service in the facility See optional mounting configurations in figure 2 The signal enhancer provides improved signal performance by amplifying radio frequency signals being received from the base station and the subscriber unit mobile phone The model Link2Cell provides signal enhancement for the entire PCS band only see the L...

Page 13: ... installation requirements and undamaged in shipment Quantity Part Description 1 Link2Cell SOHO Signal Enhancer 1 Loctite Thread locker 1 Power Converter 1 Mounting Base 2 Mounting Posts 4 Wall Anchors 4 Mounting Screws Figure 1 Package Contents Link2Cell Repeater Power Converter Mounting Base Mounting Posts 2 Wall Anchors 4 Mounting Screws 4 LOCTITE Threadlocker ...

Page 14: ...ting the Link2Cell 19 Link2Cell 19 must be mounted so the Donor antenna is orientated to receive and transmit to the cell site The Donor antenna is located on the opposite side of the unit of the LED indicators of the Link2Cell 19 with the LED s either at the bottom or the top to keep the orientation of the Donor antenna correct with respect to the direction of the cell site and which wall you des...

Page 15: ...will indicate how to position the Link2Cell donor antenna signal enhancer unit Remove the 2 protective caps of the mounting holes from the selected side of the Link2Cell taking into consideration the 3 LED s must be facing you or the desired area of coverage Apply Loctite to the threads of the mounting posts and install hand tighten only into the open mounting holes of Link2Cell unit Remove Protec...

Page 16: ... hardware 4 Wall anchors and 4 mounting screws In a downward sliding motion hook the Link2Cell Unit onto the secured mounting base Connect the Power Converter into the Link2Cell unit and the plug power converter into an 110V outlet Attach Mounting Base to Mounting Surface Using Appropriate Mounting Hardware Slide Link2Cell Unit into Mounting Base Plug Power Converter into Unit Plug Power Converter...

Page 17: ...uency MHz 1850 to 1910 Downlink EIRP Transmit Power dBm 15 Uplink EIRP Transmit Power dBm 28 System Gain dB 40 to 79 Gain Flatness dB 2 Noise Figure dB 6 Spurious Output Rated Power FCC Regulations dB 13 Fc 885 KHz CDMA only dBc 45 Fc 1 25 MHz dBc 26 2 tone 1 dBm each DL dBc 60 1 dB Compression dBm UL 22 DL 22 IP3 dBm UL 41 DL 41 Operating Temperature degrees C 0 to 50 Power Source 115 VAC 9 VDC 1...

Page 18: ...mber Solid Indicator Weak RF Signal New Installation Check Antenna alignment with cell site and recycle power Weak RF Signal Previously working recycle power No Change Replace Unit Green Flashing Indication Unit is in initial system initialization if still flashing after 5 minutes replace unit No signal improvement to subscriber unit Recycle power to unit Watch indicators for gain settings Gain Se...