background image

 

Manual-EMT-928 

9/13 

Connection 

1.

 

Connect the RCA output connectors with the phono input terminal your amplifier. 

2.

 

Connect the GND-socket with the GND-terminal of the same amplifier. Use the GND cable delivered in the accessories box. 

3.

 

Connect the IEC C14 socket to the mains. Use the power cable provided by your distributor. 

4.

 

Switch on the internal charger. 

The EMT 928 features a unique battery power system, which allows listening music while the turntable is fully disconnected from the mains. Charging of 
the battery is controlled by an integrated micro-processor. 

-

 

To prevent self-discharge of the battery, always keep the charger on while the turntable is not in use. 

-

 

For best performance, switch the charger off while listening to the music. 

 

Summary of Contents for 928 II

Page 1: ...on Turntable Thank you for choosing the EMT turntable Please take time to install and adjust your product properly Remember to work carefully and to follow the instruction manual step by step You will find actual information about our products on www emt tontechnik ch ...

Page 2: ...s elsewhere in the user manual Unauthorized disassembly or modifications whatsoever of the product will also void the warranty In any case of warranty claims please contact your dealer EMT 928 Configuration The EMT 928 turntable can be ordered in two different configurations 1 EMT 928 II The product is delivered with no tonearm installed For installing the tone arm please refer to page 5 of this m...

Page 3: ...ging device Please open the packaging and remove the content and layers step by step Place the product parts on an even base keeping them ready for assembling Remove the top packaging layer 1 Remove the platter 2 Make sure the medium layer 3 is free around the tonearm area and remove it 1 2 3 ...

Page 4: ... 13 Remove the turntable chassis 4 Remove the power cable 5 Remove the accessories box 6 Inside it you will find Screwdriver for adjusting the speed Hexagon key to release the transport lock Spare belt GND cable 4 6 5 ...

Page 5: ...efore moving it from the horizontal position Installation Process Remove the tonearm cover 1 from the chassis Make sure the tonearm adapter 2 suits the specification of your tonearm Please ask your dealer for support Install your tonearm Follow the manual provided by the tonearm manufacturer Solder the GND wire of the tonearm to the GND terminal 3 Solder the right channel output wire to the relate...

Page 6: ...ightly and keeps it in position To release the transport lock please follow the following steps 1 Release 4x hexagon screws 1 2 Remove 4x hexagon screws 1 completely 3 Move both locking cylinders 3 out of the sub platter 2 4 Turn both locking cylinders 180 around their axis 5 Reinsert 4x hexagon screw and tighten them 6 Sub platter incl belt and flywheel shall be free turning now 3 1 2 180 180 ...

Page 7: ...e take care of this mat to avoid damage during installation 1 Guide the main platter 1 carefully and absolutely vertically from above on the sub platter 2 Make sure the main platter is bearing completely on the sub platter 3 If needed dress the inlay mat 2 in the marked area 3 so the record will lay on an absolutely even surface Removing the platter Carefully lift the main platter up to remove it ...

Page 8: ...decoupling feet red marked in and out of the main chassis Please use a level gauge to level the unit exactly horizontal Make sure at least one of the spikes is fully tightened The feet are guided not only by a fine pitch thread but by a cylindrical fitting as well Therefore no locking of the spike is needed The maximum range of adjustment is 4mm ...

Page 9: ...s Use the power cable provided by your distributor 4 Switch on the internal charger The EMT 928 features a unique battery power system which allows listening music while the turntable is fully disconnected from the mains Charging of the battery is controlled by an integrated micro processor To prevent self discharge of the battery always keep the charger on while the turntable is not in use For be...

Page 10: ...to the next page Operation Switch 1 Function Battery LED Info Battery level Platter Stop Charging if charger is switched on Green steady glowing Pure listening mode OK Green blinking slowly Maintenance charging Fully charged Platter Run Pure listening mode Connected to drive only Green blinking fast Charger switched off OK Red glowing steady Pure listening mode RESERVE Platter Run Charging if char...

Page 11: ...so you get acces to the potentiometers from undeneath Set the screwdriver thru the holes at the bottom of the device and connect it to the internal potentiometers Turning the key clockwise will increase the speed turning it counter clockwise will decrease it Cleaning For cleaning the EMT 928 please use a soft and clean towel The high density inlay of the platter shall be cleaned with a wet microfi...

Page 12: ...red together with the turntable Please contact your dealer for further information 1 Remove the main patter refer to page 7 2 Fully remove the locking cylinder 1 refer to page 6 3 Remove the old belt 4 Clean the tread of both the pulley 2 and the sub platter 3 5 Change the belt for e new one Make sure the positioning of the belt is correct in the tread 4 6 Install the locking cylinder 1 again refe...

Page 13: ...dB 75dB Speed up time 10s 12s 20s Battery service life Standard LED Green 40h 38h 30h Battery service life Reserve LED Red 10h 9h 7h Dimension 480x340x100mm Weight 23kg Input voltage 100 240VAC 50 60Hz Output terminal RCA with separated tonearm ground Mounting distance tonearm 215 245mm prepared for EMT 9 inch tonearm Version V1 2 Date 11 11 2022 ...