7.0 ELC Device Configuration
Once the ELC
is powered and connected to the ECU’s CAN bus, the following steps should be
taken to complete the setup. All setup and device monitoring is done using Emtune so this
software needs to be installed and connected to the ECU.
7.1 ELC Single Device Setup
This section outlines the setup procedure for a single device and involves 2 steps:
1.
Device Detection by the ECU
2.
ECU CAN Bus configuration
7.11 ELC Device Detection
To confirm the ELC device has been detected, connect to the ECU using Emtune. Open the
ECU Runtime menu (F3) and select the Communications Tab. Within this tab there will be a
list of Emtron CAN devices the ECU has detected. It will list:
1.
CAN Device Model
2.
Device Serial Number
3.
Device Firmware Version
4.
Device Hardware Version
5.
CAN Base Address ID
With a single ELC device connected, the data should look as shown in Figure 7.0/7.1.
Important
:
▪
At this stage the ECU has only detected the device. It has not been configured to an ECU
CAN Channel so the ELC data is not yet available.
▪
Note the CAN Base Address ID. This is required in the ECU CAN setup. The factory setting
is ID 671 for the ELC and ELC2M.