EMTRON ELC USER MANUAL
WWW.EMTRON.WORLD
© EMTRON AUSTRALIA PTY LTD MARCH 2018
25
Continuation:
CAN ID
Name
Multiplier Offset
Units
Example
671/0x28F
Index = 0
1
0
Lambda 1
0.001
0
La
897 = 0.897 La
Pump Current 1
0.001
0
mA
132 = 0.132mA
Fault 1
1
0
Status 1
1
0
Heater 1 DC
1
0
%
42 = 42%DC
ID
672 /0x290 (Default)
Data
Lambda Channel 2
ID Type
Standard 11-bit identifier
Direction
Transmit from Device
Length
8 bytes
Tx Rate
100Hz/10ms
CAN ID
Name
Start bit
Length
(bits)
Byte Order
Data Type
672/0x290
Index = 0
0
8
Little Endian
Unsigned
Lambda 2
8
16
Little Endian
Unsigned
Pump Current 2
24
16
Little Endian
Signed
Fault 2
40
8
Little Endian
Unsigned
Status 2
48
8
Little Endian
Unsigned
Heater 2 DC
56
8
Little Endian
Unsigned
Continuation:
CAN ID
Name
Multiplier Offset
Units
Example
672/0x290
Index = 0
1
0
Lambda 2
0.001
0
La
897 = 0.897 La
Pump Current 2
0.001
0
mA
132 = 0.132mA
Fault 2
1
0
Status 2
1
0
Heater 2 DC
1
0
%
42 = 42%DC