Scenario 2 (controlled Non-CAN charger)
In the following figure
2.7
a system using controlled Non-CAN charger is presented. In this scenario
Non-CAN charger is directly connected to the battery pack and controlled using low and high power
relays. For this set-up firstly connect battery to BMS mini: connect "Battery (-)" to "Battery (-)
Figure 2.7: Controlled Non-CAN charger installation diagram
terminal" and "Battery (+)" to "Battery (+) terminal" using power cables. Now charger can be
connected: using power cables connect "Charger (-) terminal" to "Battery (-)" and "Charger (+)
terminal" to "Power (+) terminal". Now we will setup control/indication components. Low power
AC Sense Relay of type NC (normally closed) should be connected in series to the AC Mains, which
purpose is to signal whenever power is present. Connect one output of this relay to ’I1’ pin of
pin function connector, which is displayed in figure
2.8
. Other output connect to ’-’ pin of the
safe 10-pin connector. Use high power relay to connect Non-CAN charger as shown in figure
2.7
.
Connect one power relay input to "Battery (+) terminal" and another one to ’O1’ pin of pin function
connector. Wiring is completed what is left is to enable these "AC Sense" and "Enable Charger"
Figure 2.8: 10-pin Pin Function connector
11