19
Over-voltage protection count
The number of times Over-Voltage protection has been activated.
Additionally contains the timestamp of the last occurrence.
20
Discharge over-current protection
count
The number of times Discharge Over-Current protection has been
activated. Additionally contains the timestamp of the last
occurrence.
21
Charge over-current protection count The number of times Charge Over-Current protection has been
activated. Additionally contains the timestamp of the last
occurrence.
22
Cell Over-Temperature protection
count
The number of times Over-Temperature protection has been
activated. Additionally contains the timestamp of the last
occurrence.
25
Pre-heat stage count
The number of time the "Pre-Heating" stage of the charging
process has been entered.
26
Pre-charge stage count
The number of time the "Pre-Charging" stage of the charging
process has been entered.
27
Charging stage count
The number of time the "Charging" stage of the charging process
has been entered.
28
Balancing stage count
The number of time the "Balancing" stage of the charging process
has been entered.
29
Charging finished count
The number of time the "Charging Finished" stage of the charging
process has been entered.
30
Charging error occurred
The number of time the "Charging Error" stage of the charging
process has been entered.
32
Charge restarts count
The number of times the charging process automatically restarted
when maximum cell voltage dropped below "Recharge Voltage"
parameter value.
33
Over-Temperature protection count
The number of times Over-Temperature protection has been
activated. Additionally contains the timestamp of the last
occurrence.
34
Min Internal Temperature
The lowest recorded internal temperature. Additionally contains
timestamp of when this value was recorded.
35
Max Internal Temperature
The highest recorded internal temperature. Additionally contains
timestamp of when this value was recorded.
26