KPX 100 Instuctions.doc Rev 1.6 7/10//2018
*
4
1
#
4
0
0
#
1
1
#
?
?
?
?
2
#
?
?
?
?
#
8
9
0
0
KPX 100 Quick Start For Single-User Mode
1.
Connect Power
12V DC to 24V AC/DC to terminals (+) and (-)
2.
Connect the OUTPUT 1
N/O and COM to OPEN contacts in the operator
(see operator manufacturer’s manual for proper terminals)
3.
To Enter Programming mode:
Press 0000 *
(This is the factory set Master Code change for security)
4.
The KPX 100 is shipped in multi user mode from the factory
5.
To change to Single User Mode:
Press 8900 then #
6.
To set PERSONAL MASTER CODE:
Press 0 and 4 digits and #
To program Relay users
7.
To set USER CODE Relay 1:
Press 1 then 4 digits and #
8.
To set USER CODE Relay 2:
Press 2 then 4 digits and #
9.
To set OUTPUT for 10 seconds:
Press 402 then #
(40 is output program code. Time may be from 1 – 999 seconds)
10.
To Place Relay 1 in Toggle or Latch Mode:
Press 41 then #
11.
To Exit programming:
Press *
For additional detailed information regarding additional functions, connection to door controls, alarms and trouble shooting please refer to the
manual. (see index)
0
0
0
0
*
Pg 2
0
?
?
?
?
#
*This must be done
after changing modes
Record the new code
Note:
Each successful program action
is followed by (2) "beeps" confirming
acceptance
Summary of Contents for KPX 100
Page 2: ...KPX 100 Instuctions doc Rev 1 6 7 10 2018...
Page 3: ...KPX 100 Instuctions doc Rev 1 6 7 10 2018...
Page 6: ...KPX 100 Instuctions doc Rev 1 6 7 10 2018 Pg 3 D A P Reset see Page 5...
Page 7: ...KPX 100 Instuctions doc Rev 1 6 7 10 2018 Pg 4...
Page 12: ...KPX 100 Instuctions doc Rev 1 6 7 10 2018 MASTER CODE 8 9 0 0 MASTER CODE 8 9 0 1 Pg 9...
Page 19: ...KPX 100 Instuctions doc Rev 1 6 7 10 2018 Pg 16...
Page 21: ...KPX 100 Instuctions doc Rev 1 6 7 10 2018 Pg 18...
Page 22: ...KPX 100 Instuctions doc Rev 1 6 7 10 2018 Pg 19...