OPERATING THE SMART ECON ROOM CONTROLLER
16
smart Econ - emz-HCW - 180116
Operating the smart Econ room controller
Heating
• To readjust the desired room temperature, turn the setting wheel to the desired temperature differ-
ence.
Example:
The programmed room setpoint temperature is 21 °C.
The room controller is on 2.Step adjusted in direction
+
.
This results in a desired room temperature of 23 °C.
Special functions
• If you want to heat during the set-back times (party mode), turn the setting wheel to the end posi-
tion
+
.
The connected heating circuit changes continuously to day mode until the setting wheel is reset.
• To activate the setback function (e.g. holiday), turn the setting wheel to the end position
-
.
The connected heating circuit changes to night mode until the setting wheel is reset.
Range +3 to -3
The room temperature setpoint is changed by the value set.
End position
+
Party function for the assigned heating circuits.The highest
room temperature setpoint entered is used, irrespective of the
time program.
End position
-
Setback function for the assigned heating circuits.The tem-
perature is controlled to the setback temperature entered for
this room.