SETTINGS DURING OPERATION
smart Econ - emz-HCW - 180116
35
›HOLIDAY PERIODS‹ menu
(Example, depending on the selected system)
In the ›HOLIDAY PERIODS‹ menu, first select whether the setting is to apply to the entire system or
only to the individual heating circuit.
• Enter the start and end dates for the holiday.
Notes:
To delete a holiday period, enter the date 00.00.
More than 10 holiday periods can be set for the entire system,
for a single heating circuit, however, only one.
On these holidays, the room temperature is controlled to the frost protection room temperature.
See “Operating mode ›FROST PROTECTION‹” on page 28.
On the last day of a holiday period, the room temperature is controlled to the setback temperature.
If a programmed holiday period has passed, the entry is automatically deleted.
PLEA SE SELECT
^
ENTIRE UNIT
HEAT CIRCUIT 1
HEAT CIRCUIT 2
HEAT CIRCUIT 3
HEAT CIRCUIT 4
BA CK
i
HOLIDA Y PERIODS
^
ENTIRE UNIT
new holiday f rom
00.00
until
00.00
BA CK
i