101
Professional mode
These parameters must be set by the
fitter based on the applicable national
regulations. ›Function‹ is used to de-
fine the period in days (1 - 7) during
which legionella reduction must have
occurred at least once.
›t-ON‹ is used to define the time of a
possibly required reheating cycle.
›T legionellae‹ defines the disinfection
temperature. ›t monitor‹‹ is used to
define the minimum disinfection time.
Continue with ›Tank cooling‹.
Activation and setting of the an-
ti-freeze protective function for the
collector.
Via ›T ON‹, enter the anti-freeze
protection temperature for water-filled
plants.
When anti-freeze products are used,
the type and the proportion can be
entered; the anti-freeze protection
temperature is calculated automati-
cally.
In the case of plants with two
tanks, the source of the anti-freeze
protection heat must be selected
by specifying ›Priority tank‹ or
›Secondary tank‹.
Continue with ›Anti-legionellae‹.
Activation
T ref
T ON
Glycol type
Tank
5.0°C
5.0°C
Water
Priority tank
1.5.3 Antifreeze prote...
25.08.2012
10:42
Repetition
T legionellae
t ON
t monitor
Activation
1 day
60.0°C
01:00
60min
1.5.4 Anti-legionellae
25.08.2012
10:43