103
Professional mode
›dT monitoring‹ is used to define the
criteria which lead to fault detection.
›dT coll/stor‹ is used to define a
differential temperature between
collector and tank, and ›t max.coll/
tank‹ for the relevant period of time.
If ›dT coll/stor‹ is exceeded within ›t
max.coll/tank‹, the controller detects
a fault.
With ›Monitoring of‹, the monitoring
of the feed and return temperature
of the heat counter can be selected.
Continue with ›Volumenstrom‹.
The following items appear under
›1.6. Monitoring‹ next to the opera-
tion mode menus:
- ›DiffTemp‹
- ›Volume flow‹
- ›Coll.Emerg.OFF‹
- ›Sensor balancing‹
Call up the menu item ›DiffTemp‹.
Error list
Differential temp
Volume flow
Collector Emergency OFF
Sensor balancing
1.6 Monitoring
25.08.2012
10:44
dT coll/stor
t max coll/tank
Monitoring of
30.0K
10min
---
1.6.2 dT-monitoring
25.08.2012
10:44
Summary of Contents for smart Sol plus