20
Hydraulic systems
Boiler with disable
recharge feature,
efficiency optimization
Boiler with disable
recharge feature
time-/temperature-
controlled, in combination
Boiler, e. g. using fossil
fuels/ solid fuels/
heat pump etc.
Hydraulic
heat exchanger
Temperature probe
Switching valve
Solar collector panel
Secondary yield
Solar collector panel
Main yield
Swimming pool
Warmwasserspeicher/
Pufferspeicher mit
Wärmetauschern
Warm water /
buffer tank without
heat exchanger
Heating pump
Return line
Supply line
Note!
Define structure and design of the plant already when planning
the entire solar thermal system and align the design with the
one of the hydraulic systems of the controller!
If you want to complete an existing system or replace
the existing controller, please make sure that
smart Sol plus is compatible with the existing configuration!
The sensors are connected to TS1 to TS10, the order not being
significant; pumps and valves are connected to RO1 to RO4 / REL - The
interfaces are assigned to the functions in question on commissioning.
Summary of Contents for smart Sol plus
Page 1: ...Equipment Excellence ...
Page 7: ...7 Dimensions 218 mm 51 mm 109 mm dmax 5 9 mm 109 mm 140 mm 30 mm 48 mm 218 mm 5 mm ...
Page 56: ...56 ...
Page 113: ......