73
Operation mode
›1.3.6 Fixed temp.c...‹ appears.
Here, the temperature values for
the collector panels are entered which
are to be achieved via control of the
pump delivery rate in question.
The factory settings of the
smart Sol plus can be used
for almost all plants.
Return to ›1.3 Basic functions‹.
Continue with ›Increase return T‹.
›1.3.10 Post Heatin...‹ erscheint.
The reheating control reacts to the
values of the top tank sensor. If the
temperature falls below ›t charge‹
minus the hysteresis, the control
activates the reheating cycle via the
heating boiler. When the set value
is reached the reheating cycle is
stopped.
Return to ›1 Main menu‹.
Continue with ›Efficiency functions‹.
›1.3.8 Increase retu...‹ appears.
Parameters for return flow
temperature increase can
be defined here.
Ask a fitter before making
changes at this point.
Return to ›1 Main menu‹.
Continue with ›Post Heating Request‹.
T-fixed 2
70.0°C
1.3.6 Fixed temp.cont...
25.08.2012
10:27
Activation
T ON
T OFF
T min
8.0K
4.0K
15.0°C
1.3.8 Increase return ...
25.08.2012
10:27
Hysteresis
Time block 1
Time block 2
Time block 3
Time block 4
Time block 5
Time block 6
10.0K
1.3.10 Post Heating R...
25.08.2012
10:27