Professional mode
The following items appear under
›1.4. Efficiency funct.‹ next to
the operation mode menus:
- ›Low-Flow‹
- ›Quick-charging‹
- ›Efficient tank-charge‹
Call up menu item ›Low-Flow‹.
Tank quick charging changes over
from dT control to fixed temperature
control.
›T ON‹ and ›T OFF‹ define the
change-over range and ›T targ. Coll.‹
the fixed temperature on the collector.
An upper tank sensor is
required for quick-charging.
Continue with ›Disable recharge‹.
Here, the switch-ON temperature
can be defined for low-flow plants.
Continue with ›Quick-charging‹.
Low-Flow
Quick-charging
Disable recharge
Efficient tank-charge
1.4 Efficiency functions
25.08.2012
10:38
Activation
T ON
60.0°C
1.4.1 Low-Flow
25.08.2012
10:38
Activation
Sensors
T ON
T OFF
Collector target temp.
---
48.0°C
52.0°C
70.0°C
1.4.2 Quick-charging
25.08.2012
10:38