98
Professional mode
If the plant has been designed accord-
ingly and a system involving disable
recharge selected, the appropriate
parameters are set here.
Here, the time control and/or the
temperature control are activated -
possible for all systems with heating
boiler control.
Time and temperature control
can be used in combination.
Select the time slot
via ›Start‹ and ›End‹.
Select the minimum temperature
via ›T min tank‹.
Here, the efficiency-optimized disable
recharge is enabled and activated -
possible for all systems with heating
boiler control.
Set ›factor 1‹.
Factor 1 assesses solar yield,
factor 2 assesses comfort.
By reducing factor 1, the expected
solar input gets a higher weighting.
Set ›factor 2‹.
Reducing factor 2 will
decrease comfort.
Determine under ›T floating‹ whether
the temperature is to be measured
on the upper or lower tank sensor.
Enter the minimum tank temperature
via ›T min tank‹.
Continue with ›Efficient tank-charge‹.
Activate time program
Start
End
Activat, T-min
T min. tank
Activat.Tmin float
00:00
00:00
45.0°C
1.4.3 Disable recharge
25.08.2012
10:39
Factor 1
Factor 2
T target
T floating
T min. tank
4.0
2.0
45.0°C
upper tank sensor
45.0°C
1.4.3 Disable recharge
25.08.2012
10:39