1.3.5 dT control
04. 07. 2015
10:37
Activation dT 1
Activation dT 2
dT 1
dT ON 1
dT OFF 1
2.0k
8.0K
4.0K
PROFESSIONAL MODE
Here, new commissioning
can be started - e. g. if a new
hydraulic system is to be selected.
=> ›Commissioning mode‹ as of page 45.
Continue with ›Delta T control‹.
If control algorithms have been defined as
›dT‹ under ›1.3.7 Output parameter‹, the
appropriate outputs can be configured here.
Via ›dT ON‹, the switch-ON temperature,
via ›dT OFF‹, the switch-OFF temperature
and via ›dT targ.‹, the target differential
temperature are set. (Differential temperature
between collector and tank, bottom).
Continue with ›Fixed T control‹.
Note!
The ›dT targ.1‹ parameter is displayed in the
›1.3.5 dT control‹ menu for systems with 2 collector fields.
With ›dT targ.1‹ the maximum temperature
difference between both collector sensors is specified.
Once this value is exceeded, the pump of the „colder“ collector field
is deactivated in order to increase efficiency.