HYDRAULIC SYSTEMS
smart Stove - 0142 - 42WMSUGAT2-C
21
Hydraulic system 5: Pellet stove
Connection of hydraulic system 5
TS1: Stove sensor
TS2: Tank sensor, top
TS3: Tank sensor, middle
TS4: Tank sensor, bottom
TS5: Supply line sensor
(optional)
TS6: Outdoor temperature sen-
sor (optional)
RO1: Request for heat from
pellet stove
RO2: Blocking of space heating
pump
REL: Additional heating
TS6
TS5
RO2
TS1
TS2
TS3
TS4
RO1
REL
Supply line sensor
Outdoor temperature sensor
Tank sensor, middle
Additional heating,
Tank sensor, bottom
Stove sensor
Tank sensor, top
Power supply (230 V AC)
Request for heat (230 V AC), see
“Connection for request for heat to
RO1” on page 48
Blocking of space heating pump
(230 V AC), see “Blocking connection of a
pump to RO2” on page 48