THERMOSTAT FUNCTIONS
28
smart Stove - 0142 - 42WMSUGAT2-C
Thermostat functions
The free outputs of the controller can be used as thermostats and/or timers for various applications.
The thermostat functions must be defined in professional mode under ›1.3.1 Thermostat‹, see
“Basic functions” on page 55.
The thermostat functions can also be activated or deactivated in operation mode under ›1.3.1
Thermostat‹, see “Basic functions” on page 36.
Various thermostat and/or timer functions can be defined:
Temperature thermostat “Heating”
Temperature thermostat “Cooling”
Timer function
T OFF > T ON The output is deactivated once
the ›T OFF‹ temperature is reached, and acti-
vated once the ›T ON‹ temperature is reached.
T ON > T OFF The output is activated once the
›T ON‹ temperature is reached, and deactivated
once the ›T off‹ temperature is reached.
The output is activated within a selected time
frame.
T
t
ROx
T OFF
T ON
T
t
ROx
T ON
T OFF
8:00
9:00
t
ROx