ELECTRICAL CONNECTION
smart Stove - 0142 - 42WMSUGAT2-C
45
The spring-type terminals for the power supply, RO1, RO2 and REL, and for TS1 to TS8 can accom-
modate solid wires up to a cross section of 1.5 mm
2
. Appropriate stranded wires must be preassem-
bled with cable end sleeves.
For the strain relief device function, TS1 to TS7 and REL require cable diameters of at least 5 mm,
for Power, RO1, RO2 at least 7 mm.
The strain relief fixture can be slightly reworked to fit larger cable diameters without producing sharp
edges. For a larger number of sensor lines, cable straps can be used to support the strain relief.
Cable preparing
NOTICE
Before closing the terminal cover, make sure the strain relief
device is tightened safely.
Check once more that all cables are in good condition and
connected correctly.
9-10 mm
max.
35 mm
The strain relief device can only ensure solid clamping if the cables are
not stripped to a length of over 35 mm.
Insulation of the individual wires must be removed over a length of 9 -
10 mm to ensure safe electric contact in the spring-type terminal.
Stranded wires must be provided with cable end sleeves!
For connection, press the actuation push button of the
spring-type terminal using a screwdriver and insert the
wire to its stop in the appropriate port.
Release the actuation push button and pull the
cable slightly to ensure that it is safely clamped.