COMMISSIONING
52
smart Stove - 0142 - 42WMSUGAT2-C
›0.7.1 Test outputs‹ appears.
The menu depends on the selected hydraulic system.
Select an output, acknowledge, select ›On‹ on the knob and
activate it. The connected pump and/or the connected valve
must now be activated.
Complete the test operation by pressing ›Next‹.
NOTICE
If the hydraulic installation does not comply with the standard,
or if special products were used which cause incorrect valve
positions during test operation, the ›Inverted‹ option must be
activated by accessing the corresponding output menu 1.3.7 in
professional mode after commissioning.
The controller will then exchange energized and de-energized
conditions.
You can mirror the hydraulic scheme display, i.e. the buffer
tank will be displayed on the other side of the boiler.
Activate ›Mirror system‹ if your plant is that way.
Note: ›Mirror system‹ does not influence the functions of the
controller.
The further menu items depend on the selected hydraulic sys-
tem.
If a temperature sensor for space heating is installed, select it
by the ›Supply Sensor‹ item.
If an outdoor temperature sensor is installed, select it by the
›Outdoor Sensor‹ item.
Note: The availability of temperature sensors depends on the
selected system. By selecting a temperature sensor, the
regarding functions are enabled simultaneously.
0.7.1 Test outputs
17.03.2016
09:14
RO1
Off
RO2
Off
REL
Off
TS8
Off
Next
0.7 Checklist
17.03.2016
09:14
Test outputs
Mirror system
Supply Sensor
---
Outdoor Sensor
---
HE signal TS7
---
0.7 Checklist
17.03.2016
09:14
Test outputs
Mirror system
Supply Sensor
TS5
Outdoor Sensor
TS6
HE signal TS7
---