SETTINGS IN THE PROFESSIONAL MODE
smart Stove - 0142 - 42WMSUGAT2-C
67
Summary of parameters in ›Basic functions‹
Items marked by an asterisks * are only available in professional mode.
Menu/parameter
Default Range
Unit
Description
Hydraulic system
Basic functions
1 2 3 4 5 6 7
Control parameters
x x x x x x x
Add. heat enabled
Yes
No/Yes
Recharging of the
tank by the additional
heating
x x x x x x x
Charge start
58
30 ... 90
°C
Minimum stove tem-
perature for starting
the loading pump
x x x x x x x
Charge offset *
5
2 ... 15
K
Temperature offset for
starting the speed
control of the loading
pump
x x x
Act. ZV below *
43
20 ... 90
°C
Lower temperature
threshold for activa-
tion of zone valve
x x
x
Offset ZV act. *
2
1 ... +10
K
Temperature offset
(hysteresis) for zone
valve activation
x x
x
Ext. AH pump On *
5
1 ... 5
K
Switch-on tempera-
ture offset (hysteresis)
for additional heating
pump
x
Ext. AH pump Off *
2
-5 ... +2
K
Switch-off tempera-
ture offset (hysteresis)
for additional heating
pump
x
DPD *
0
0 ... 50
min*K
Dynamic pump delay
x x x
High. imm. heater *
No
No/Yes
Force start and stop
sensor to TS2 for
additional heating
x x x x x x x