SETTINGS IN THE PROFESSIONAL MODE
70
smart Stove - 0142 - 42WMSUGAT2-C
Delay add. heat *
72
0 ... 96
h
Time delay for heating
cycle with additional
heating
x x x x x x x
Day *
Friday
Monday ...
Sunday
day
Day of week for disin-
fection
x x x x x x x
Interval *
7
1 ... 14
days
Repetition interval for
disinfection
x x x x x x x
Allow any heat *
Yes
No/Yes
Use any heat source
for disinfection
x x x x x x x
Space heating
x x x x x x x
Block SH below *
43
20 ... 90
°C
Tank temperature for
blocking space heat-
ing
x
x x x
x
Offset SH block *
2
1 ... +10
K
Temperature offset
(hysteresis) for block-
ing space heating
x
x x x
x
Req. add. heat
50
20 ... 90
°C
Setpoint for request
for heat from addi-
tional heating. If the
tank temperature falls
below this tempera-
ture the request will
be activated
x x
x x x
Offset. add. heat *
+5
1 ... +20
K
Offset for deactivat-
ing request for heat
from additional heat-
ing
x x
x x x
Req. stove
55
20 ... 90
°C
Required tank temper-
ature for space heat-
ing with stove
x x x x x x x
Offset stove *
+10
1 ... +50
K
Tank temperature off-
set (hysteresis) for
space heating with
stove
x x x x x x x
Menu/parameter
Default Range
Unit
Description
Hydraulic system
Basic functions