7.13 MAINTENANCE OF THE HYDRAULIC CONTROL
Check the level of the circuit once a month or every 250 hours.
7.13.1.
Return the mast to the out-of-service position.
7.13.2.
Remove the control plug for the handlebar casing.
7.13.3.
Check that the oil reaches the inside edge of the hole
!
ATTENTION
: The machine should be stopped or out of service.
To top up the circuit.
7.13.4.
Remove the upper plug from the pump housing in the handlebar (2).
7.13.5.
Push the handle to its forwardmost position.
7.13.6.
Top up through the hole in the oil pump with Shell MORLINA 100 oil and using the
handle, pump to make the oil go down. Repeat this operation until the whole circuit is full
of oil.
7.13.7.
Close the control port.
7.13.8.
Close the fill port.