7. TWINSTAR NANO’s cleaning & replacement 

1)  Cleaning  solution  is  diluted  20cc  sodium  hypochlorite  with  1000cc 
water to soak for 3 hours and use soft sponge wipe the around plastic 
part, do not wipe the electrode.  
2) NANO part is a consumable item and will need replaced periodically.  
If you are using this product in accordance with the instruction manual,  
can be used for 9 months to 14 months. In order to maintain its 

performance, please purchase  TWINSTAR NANO part separately.   
 

8. Caution 

TWINSTAR  can  only  be  used  the  fresh  water  aquarium,  not  be  used 
saltwater aquarium, also not be used for any other purpose. 
1. Please read this manual and follow the description. 
2. Please check whether animal or plants (including ornamental fish) are 
safe  for  days  after  installing  the  product.  We  are  not  take  the 
responsibility for fish die after your review.  
3. Do not wipe or grab TWINSTAR NANO’s electrode. 
4. Please supply the power after all parts installed. 
5. Do not put your hands inside the tank when product operates.   
6. Do not drop or give excessive force. 
7.  Must  be  put  off  the  power  button  when  installation  or  changing 
water. 
8. If you will not use product for long time, please unplug  the power 
cord.   
9. Do not use the wrong way, modify or disassemble the unit. 
10. Keep the product from child. 

Please contact agent for product A/S. 

9. Warranty 

 

1. The warranty period is one year after purchase excepting 

NANO.(diffuser part) 

2. We do not warranty for consumer negligence. 

3. Must keep this warranty for free A/S. 

4. This warranty is not reissued, please keep it. 

5. After the warranty period, please contact agent for A/S. 

6. NANO’(diffuser)s warranty period is 6 months.  

7. This warranty is void if the label bearing the serial number has been 

removed or defaced. 

  

Visit our official web site or FACE BOOK 

for further info. 

Official web site : www.twinstarnano.com 
Face Book : www.facebook.com/twinstarnano 
Blog : http://blog.naver.com/twinstarnano 

High dense planting with aquatic plants is essential to make a 
healthy and fancy aquarium. 

If dust generates during setting, removing dust by draining or 
exchanging water is necessary. 

Changing water is in accordance with guideline by soil manufacturer. 

1

 

S1day  “ Dense planting & Remove dusts” 

At the initial stage, because of rich nutrition from soil, from the third 
day algae will germinate and from the 10

th

 day, it will be visible to the 

naked eye. 

To inhibit algae from the beginning of germination, it is recommended 
to install TWINSTAR in s 5days or 10 days at the latest. 

2

 

S3~5days  “ Installation  TWINSTAR “ 

Although TWINSTAR’s effect on green algae is over 80%, to 
remove green algae completely, put aquatic animals eats algae.  

By putting these animals at this period, even beginner aquarist 
can make a perfect aquarium without green algae. 

3

 

S6days  “Put  algae Eater, Yamato shrimp & Siamese “ 

TWINSTAR User Guide (New set Aquarium

45~60cm tank 

2 Yamato shrimps,    2 Siameses 

90cm tank 

3 Yamato shrimps,    3 Siameses 

4

 

S8days  “ Injection of Carbon dioxide” 

Aquatic plants start taking their roots normally from the 6th day 
after setting, apply CO2 little at first, and then increase the 
amount gradually. 

5. User Guide 

 
1)  For  new  setting  aquarium,  install  the  product  after  3-5  days  after 
removal debris completely.    
2)  For  existing  aquarium  set  over  1  month,  install  the  product  after 
removal algae and debris completely.  
 
If a little bit of salt is included in fresh water for medical remedy, please 
remove salt before install the product. 
 
 

6. How to Reset the mode (Reformat algorithm) 

TWINSTAR  has  ALC  Program  built  in  which  operates  depending  on 
aquarium’s  environmental  changing.    To  reset  the  mode  means 
reformat  program  to  the  initial  program.    Reformat  is  needed  if  you 
reset  your  aquarium  or  make  new  aquarium  and  install  TWINSTAR 
again.   Press the power button over 10 seconds to reset the mode. 

Not for free A/S 

1. Self repairs, Remodeling, Disassembly.   

2. Used for other purpose except install in fresh aquarium. 

3. Used for other purpose except in domestic aquarium. 

4.  Fire,  Earthquake,  Over-voltage,  lightning  and  any  other  natural 

disasters. 

Date of Purchase 

Store 

Customer Name 

Address / Phone 

Reviews: