Gasblaster LSX O&M Sept 2009.doc
7
Start Up
1.
Make sure the amber On/Off Main Power Breaker Switch is in the OFF position.
2.
Power down or close off the external incoming oxygen or dry air gas source (if equipped).
WARNING:
No liquid water should be allowed to enter the ozone generator.
WARNING:
No oil in vapor or aerosol form greater then 0.008 ppm should be allowed to
enter the ozone generator (no hydrocarbons).
3.
Completely open any back pressure control valves that may be installed in the ozone
output line.
4.
Set the Ozone Output Adjustment Knob to 0%.
5.
Turn the On/Off Main Power Breaker Switch to the ON position.
6.
Set the Gas Flow Adjustment Knob so that the Gas Flowmeter indicates a minimum of (15
SCFH – LSX-100) (20 SCFH – LSX-200) .
7.
To control the amount of ozone production, rotate the Ozone Output Adjustment Knob
clockwise. The signal demand can be seen on the Reference Meter and the activation of
the ozone generator cells will be indicated by the Ozone Output Indicator Light located on
the transformer.
Supply Air Specifications:
The quality of the air supplied to the ozone generator is critical to its proper
operation. Damage incurred from improper feed gas quality is not covered by the manufacturer
ʼ
s
warranty. Outside air enters the system through the air intake hood. A filter is installed in the hood
to prevent most contaminents from entering. It is critical that this filter remain inplace and be
cleaned on a regular basis. Water MUST be prevented from entering the air intake hood. The
system must be located so that during rain or snow conditions, the air intake hood is not subject to
rainfall, standing water, snow etc.