ENC-900 Operating Manual: Chapter 4 Configuration
21
Refer to Appendix A (page
49) for a summary of the
modem commands
&F1
&F2
Master
Slave
&F1
&F4
&F3
Master
Repeater
Slave
W Connection
Result
This parameter determines the modem response at the transition to
Data Mode from Command Mode
*W0
Reports computer (DTE) baud rate as CONNECT xxxx
W1
Reports wireless rate between modems as CARRIER
xxxx.
Z
Reset and load stored configuration
The Z command resets the modem and loads the stored
configuration.
&C DCD (Data Carrier Detect)
The &C command controls the modem’s DCD output signal to the
host microprocessor. This command determines when the DCD is
active.
&C0
DCD is always ON
*&C1 DCD on when modems are synchronized. DCD is always
on when unit is configured as Master.
&C2
DCD used for output data framing
&C3
DCD is always ON, but S120 & S121 timing is still valid
&D DTR (Data Terminal Ready)
The &D command controls what action the modem performs when
the DTR input line is toggled. The DTR input is controlled by the
host microprocessor.
*&D0 DTR line is ignored
&D1 Not
Supported
&D2
De-assert DTR to force the modem into command mode
from data mode. DTR must be asserted before putting the
modem back into data mode (The modem is put back into
data mode in the normal manner using ATA or ATO)
&D3
De-asserting DTR disconnects and resets modem. Modem
will remain in this state until DTR again goes active.
&F
Load Factory Default Configuration
The &F command resets the modem and loads the default factory
configuration.
&F1
Master Point-to-Multipoint. Designed to communicate
with modems configured as &F2 or &F3.
&F2
Remote. Designed to communicate with another modem
configured as &F1.
&F3
Repeater. Designed to communicate with modems
configured as &F1 and &F4.
&F4
Remote working with factory default Repeater and factory
default Master. Communicates directly with Repeater
configured as &F3.
Summary of Contents for ENC-900
Page 9: ...ENC 900 Operating Manual Chapter 2 Electrical Physical 5 ...
Page 17: ...ENC 900 Operating Manual Chapter 2 Electrical Physical 13 ...
Page 44: ...40 ENC 900 Operating Manual Chapter 4 Configuration ...
Page 46: ...42 ENC 900 Operating Manual Appendix A Modem Command Summary ...
Page 48: ...44 ENC 900 Operating Manual Appendix B Factory Default Settings ...
Page 50: ...46 ENC 900 Operating Manual Appendix C Technical Specifications ...
Page 54: ...50 ENC 900 Operating Manual Appendix E Approved Antennas ...