24
ENC-900 Operating Manual: Chapter 4 Configuration
S Register 101 - Operating Mode
The Operating Mode (register S101) partly defines the “personality” of the
ENC-900 module. Allowable settings for this register are 1 through 6 as
follows:.
•
S101=1 Master Point to Multipoint
•
S101=2 Peer-to-Peer Mode
•
S101=3 Remote
•
S101=4 Repeater
•
S101=5 Master - Diagnostics
The default for this register depends on which factory default is selected as
shown below:
•
Default for Factory Setting &F1 is 1 (Master Point-to-Multipoint)
•
Default for Factory Setting &F2 is 3 (Remote)
•
Default for Factory Setting &F3 is 4 (Repeater)
•
Default for Factory Setting &F4 is 3 (Remote)
1) Master
- Point to Multipoint
.
In any given network,
there is always only one Master. All other units should be configured as
either Remotes or Repeaters. When defined as a Point-to-Multipoint
Master, the modem broadcasts data to all Remotes and Repeaters in the
network, and is also the ultimate destination for data transmitted by all
Remotes and Repeaters. In addition, the Master defines the following
network parameters to be utilized by all other modems in the network (See
the appropriate sections for a complete description of these parameters):
Maximum Packet Size (S112)
Minimum Packet Size (S111)
Wireless Link Rate (S103)
Hop Interval (S109)
2) Master
–
Point to Point.
This mode of operation provides
for communication between the master and a single repeater or Remote.
The master will communicate only with the Remote or repeater which
shares a common unit address with the master. For example, if a Remote
has been assigned Unit Address 100, and the Master wishes to communicate
with that Remote, the Master’s unit address must also be set to 100. If there
are Repeaters in the network, they will pass the packet through to the
Remote, and vice versa. Because Repeaters also have Remote functionality
(i.e., a Repeater can be connected to a terminal), the Master can choose to
communicate solely with a Repeater. This would be accomplished by
assigning the same Unit Address to both the Master and the Repeater.
Only one Master can exist
for each network.
Summary of Contents for ENC-900
Page 9: ...ENC 900 Operating Manual Chapter 2 Electrical Physical 5 ...
Page 17: ...ENC 900 Operating Manual Chapter 2 Electrical Physical 13 ...
Page 44: ...40 ENC 900 Operating Manual Chapter 4 Configuration ...
Page 46: ...42 ENC 900 Operating Manual Appendix A Modem Command Summary ...
Page 48: ...44 ENC 900 Operating Manual Appendix B Factory Default Settings ...
Page 50: ...46 ENC 900 Operating Manual Appendix C Technical Specifications ...
Page 54: ...50 ENC 900 Operating Manual Appendix E Approved Antennas ...