Technical Specifications
Supply voltage
230V AC +10% -20% or 12/24V AC/DC ±10%, 50/60Hz or 9-30V DC / 7-24V AC ±10%.
Power consumption
Max. 4VA
2.5mm² screw-terminal connections.
(±1%-15sec) for hour unit, (±1%-1sec) for minute unit
4 digits, 12.5mm, 7 segment yellow LED
Wiring
Scale
Sensitivity/Accuracy
Time Accuracy
Indicator
EMC
Safety requirements
The device is designed to operate in controlled electromagnetic environment)
EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B is satisfied for EMC tests.
EN 61010-1: 2001 (Pollution degree 2, overvoltage category II)
CONTROL
Control type
Single-setpoint control
On-Off control
Control algorithm
Hysteresis
Adjustable between 0.1 ... 20.0°C.
ELECTRICAL CHARACTERISTICS
ENVIRONMENTAL CONDITIONS
Height
Max. 2000m
80 , up to
40
%
31°C decreasing linearly 50% at
°C
Ambient/storage temperature
Max. relative humidity
0 ... +50°C/-25 ... 70°C (with no icing)
-50.0 ... +110.0°C (-58.0 ... +230.0°F)
0.1°C /
±1°C
Rated pollution degree
According to EN 60529 Front panel : IP65
Rear panel : IP20
Do not use the device in locations subject to corrosive and flammable gasses.
HOUSING
Housing type
Suitable for flush-panel mounting.
Dimensions
W77xH35xD71mm
Weight
Approx. 250g (Equipment and prob a
)
fter packing
Enclosure material
Self extinguishing plastics
ENDA
EDT
1
411P TEMPERATURE CONTROLLER
Thank you for choosing ENDA EDT1411 temperature controller.
Connection Diagram
ENDA EDT1411 is intended for installation in control panels. Make sure that the device is used
only for intended purpose. The electrical connections must be carried out by a qualified staff
and must be according to the relevant locally applicable regulations. During an installation, all of the
cables that are connected to the device must be free of electrical power. The device must be
protected against inadmissible humidity, vibrations, severe soiling and make sure that the operation
temperature is not exceeded. The cables should not be close to the power cables or components.
1/3
SÝSEL MÜHENDÝSLÝK ELEKTRONÝK SAN. VE TÝC. A.Þ.
Yukarý Dudullu Barbaros Cad. Kutup Sok. No:20 34775 - ÜMRANÝYE/ÝSTANBUL/TURKEY
Tel : +90 216 499 46 64 Pbx. Fax : +90 216 365 74 01
url : www.enda.com.tr
Panel cut-out
Dimensions
Note :
1) Panel thickness
should be maximum
7 mm.
2)
If there is no 60mm
free space at the back
side of the device, it
would be difficult to
remove it from the
P
anel.
EDT
1
411P-E-01-R
Holding screw
0.4-0.5Nm.
Equipment is protected throughout
by DOUBLE INSULATION
71mm
2
9
m
m
Flush mounting
clamp
For removing mounting clamps:
Push the flush-mounting
clamp in
direction
1
as
shown
in the figure below. Then, pull
out the clamp in direction
2.
1
While cleaning the device, solvents (thinner, benzine, acid etc.) or
corrosive materials
must not be used.
4
5
SUPPLY:
NOTE:
184-253V AC
50/60Hz 4VA
Line
Neutral
230V AC
Supply
Switch
Note:
Cable size: 1,5mm²
Fuse
F 100 mA
250V AC
Fuse should
be connected
1) Mains supply cords shall meet the requirements of
IEC 60227 or IEC 60245.
2) In accordance with the safety regulations, the power
supply switch shall bring the identification of the
relevant instrument and it should be easily
accessible by the operator.
Please read this document carefully before using this product. The guarantee will be
invalidated if the device is damaged by not following instructions detailed in the
manual. The company shall not be responsible for any damage or losses however
caused, which may be experienced as a result of the installation or use of this product.
Flush mounting
clamp
Depth
Panel
2
71mm
5mm
Rubber
packing
3
5
m
m
77mm
SET
SET
E
D
T141
1
ENDA
°F
°C
Order Code
Output
Supply Voltage
EDT1411-NTC-230P
Röle -16A
230V AC +%10 -%20
24V AC %10
±
EDT1411-NTC-24P
9-24V AC/DC %10
±
EDT1411-NTC-12P
* 3
5
x 77mm sized.
* On-Off control.
* Single contact output for cooling control.
* Single
NTC
probe input.
* Offset value can be entered for
NTC
probe.
* Compressor protection parameters can be entered.
* In the case of probe failure, output state can be
selected on, off or periodical running.
* Upper and lower limits of the setpoint can be adjusted.
* Defrosting duration and interval can be adjusted.
* Temperature unit can be selected °C or °F.
* Upper and lower limits of the alarm value can be adjusted depending on the setpoint value.
* CE marked according to European Norms.
SET
SET
E
D
T141
1
ENDA
°F
°C
SN: XXXXXXXXX
1
2
3
4
5
6
7
8
9 10 11 12
EDT14
11
-NTC-230VAC-P
DIGITAL DEFROST THERMOSTAT
ENDA
INDUSTRIAL ELECTRONICS
2
3
0
V
A
C
+
1
0
%
-
2
0
%
5
0
/6
0
H
z
4
V
A
C
O
M
P
R
E
S
S
O
R
2
4
0
V
A
C
1
6
A
R
E
S
IS
T
IV
E
L
O
A
D
NTC
SENSOR
SN: XXXXXXXXX
1
2
3
4
5
6
7
8
9 10 11 12
EDT14
11
-NTC-24VAC-P
DIGITAL DEFROST THERMOSTAT
ENDA
INDUSTRIAL ELECTRONICS
2
4
V
A
C
±
1
0
%
5
0
/6
0
H
z
4
V
A
C
O
M
P
R
E
S
S
O
R
2
4
0
V
A
C
1
6
A
R
E
S
IS
T
IV
E
L
O
A
D
NTC
SENSOR
SN: XXXXXXXXX
1
2
3
4
5
6
7
8
9 10 11 12
EDT14
11
-NTC-SM-P
DIGITAL DEFROST THERMOSTAT
ENDA
INDUSTRIAL ELECTRONICS
C
O
M
P
R
E
S
S
O
R
2
4
0
V
A
C
1
6
A
R
E
S
IS
T
IV
E
L
O
A
D
NTC
SENSOR
9
-3
0
V
D
C
/
7
-2
4
V
A
C
1
0
%
4
V
A
±
SN
: X
XX
XX
XX
XX
1
2
3
4
5
6
7
8
9
10
11
12
ED
T1
4
11
-N
TC
-2
30
VA
C-P
DIG
IT
AL
D
EF
RO
ST
T
HE
RM
OS
TA
T
EN
DA
IN
DU
ST
RIA
L E
LE
CT
RO
NIC
S
2
3
0
V
A
C
+
1
0
%
-2
0
%
5
0
/6
0
H
z
4
V
A
C
O
M
P
R
E
S
S
O
R
2
4
0
V
A
C
1
6
A
R
E
S
IS
T
IV
E
L
O
A
D
NT
C
SE
NS
OR
OUTPUT
COMPRESSOR
For EDT
1
411-NTC-XXP ; Relay: 240V AC, 8A (for resistive load), NO;
1 HP 230V AC
Cos
F
= 0.5
(for inductive load)
For EDT
1
411-NTC-XXP ; Mechanical 30.000.000 operation. (None load)
240V AC ,16A in the resistive load 30.000 operation.
Life expectancy for relay