background image

D

.I

N

P

14 15 16

ENDA

 

INDUSTRIAL ELECTRONICS

SN: XXXXXXXXX

EDT3423A-230-R-RS
DIGITAL DEFROST 
THERMOSTAT

11 12 13

        

COM

           

B

        

A

8 680407 726561

  

  

 

D

E

F

.N

T

C

 

1

2

3

4

5

6

7

230V AC +10% -20%
50/60Hz  5VA

D

E

F

R

O

S

T

2

5

0

V

 8

A

~

F

A

N

2

5

0

V

 8

A

~

8

9

10

   

  T

H

E

R

.N

T

C

 

  

  

 G

N

D

Made in Turkey

C

O

M

P

2

5

0

V

 8

A

~

  

  

 

D

E

F

.N

T

C

 

1

2

3

4

5

6

7

EDT3423A-230-R
DIGITAL DEFROST 
THERMOSTAT

230V AC +10% -20%
50/60Hz  5VA

D

E

F

R

O

S

T

2

5

0

V

 8

A

~

F

A

N

2

5

0

V

 8

A

~

8

9

10

   

  T

H

E

R

.N

T

C

 

  

  

 G

N

D

11 12

  

  

D

.I

N

P

ENDA

 

INDUSTRIAL ELECTRONICS

SN: XXXXXXXXX

8 680407 726554

Made in Turkey

C

O

M

P

2

5

0

V

 8

A

~

ENDA

 

EDT3423A

  is  intended  for  installation  in  control  panels.  Make  sure  that  the  device  is  used

only  for  intended  purpose.  The  electrical  connections  must  be  carried  out  by  a  qualified  staff
and must be according to the relevant locally applicable regulations. During an installation, all of the cables  
that 

are connected to the device must be free of electrical power.

Thank you for choosing  

ENDA EDT3423A

 temperature controller

1/4

  ENDA

 

EDT

3

4

23A

 

DIGITAL THERMOSTAT

CONNECTION DIAGRAM

ENVIRONMENTAL CONDITIONS

 

Height

 Max. 2000m

 

Ambient/storage temperature

 

Relative humidity

0 ... +50°C/-25 ... 70°C (

without icing

)

Protection class

According to EN60529;      Front panel : IP65
                                    

       

Rear Panel : IP20

                                               

 

Supply voltage

 

Power consumption

Max. 5VA
2.5mm² screw-terminal connections

   ±1% 
   4 digits, 12.5mm, 7 segment  LED

 

Connection

 S

cale

 

Sensitivity

 Accuracy

 

Time accuracy

 

Display

 EMC
 

Safety requirements

 

 EN 61326-1: 2013 
 EN 61010-1: 2010 (Pollution degree 2, overvoltage category II)

ELE

CTRICAL CHARACTERISTICS

-60.0 ... +150.0°C (-76.0 ... +302.0°F)

0.1°C (Can be selected as 0.1

ºC 

or

 1ºC

.) 

±1°C  

CONTROL

 

Control type

 Single set-point control
 On-Off control

 

Control algorithm

 H

ysteresis

 Adjustable between 1 ... 20.0

 

°C.

OUTPUTS

HOUSING

 

Housing type

 Suitable for flush -panel mounting

 

Dimensions

  

 W77xH35xD61mm 

 

Weight

 

 Approx. 190g (After packing)  

 

Enclosure material

 Self extinguishing plastics.

Relative humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40°C.

  Fan 

R

elay

Defrosting Relay

Compressor Relay

Life expectancy

Without load 30.000.000 switching

,

   

  

250V AC, 8A (resistive load) 100.000 switching.

Device must be protected against inadmissible  humidity, vibrations, severe soiling and make sure that the operation 
temperature is not exceeded. The cables should not be close  to the power cables or components. 

Holding screw
0.4-0.5Nm.

 

Equipment is protected throughout by 

DOUBLE INSULATION

SUPPLY:

NOTE:

184-253V AC 
50/60Hz 4VA

Line

Neutral

230V AC
Supply

 

Switch

Note: 

Cable size: 1,5mm²

Fuse 

F 100 mA 

250V AC

Fuse should 
be connected

1)

 Mains supply cords shall meet the requirements of  

    

IEC 60227 or IEC 60245. 

2)

 In accordance with the safety regulations, the power 

    

supply switch shall bring the identification of the 

    

relevant instrument and it should be easily 

    

accessible by the operator.

1

2

71,5mm

2

8

,5

m

m

Please read this document carefully before using this product. The guarantee will be invalidated if the device is 
damaged by not following instructions detailed in the manual. The company shall not be responsible for any 
damage or losses however caused, which may be experienced as a result of the installation or use of this 
product.

Order Code : EDT3423A -           -    -             

1

2

3

1 - 

Supply Voltage

     230........230V AC
     110

........110V AC

     024........24V AC
     SM.........

10

-30V DC

 

/

 8

-24V AC

     

3 - ModBus Selection

   

                                         

     

RS.........ModBus (Optional)

     Blank.....N/A
                                                     
                     
                                   
                  

2 -  

Output

      R.......8A 

Relay

 Output

     

230V AC +%10 -%20 or 24V AC or 110V AC ±%10, 50/60Hz or 10-30V DC / 8-24V AC ±%10 SMPS

SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.

Şerifali Mah. 

 Y.Dudullu  34775

ÜMRANİYE/İSTANBUL-TURKEY
Tel : +90 216 499 46 64 Pbx.    Fax : +90 216 365 74 01
url : www.enda.com.tr

Barbaros Cad. No:18

 35x77mm size.

 On-Off control.

 Three relay outputs for cooling, defrost and fan control.

 Two NTC probe input for cooling and defrost control.

 Offset point can be entered for NTC input.

 Compressor protection parameters can be entered.

 In case of probe failure, compressor operation can be 

   set to ON, OFF or periodic.

 Selectable smart defrost feature.

 Defrost operation can be performed to evaporator 

    temperature, time-dependent or manual.

 Lower and upper limits of the set point can be set.

 Defrost time and intervals can be adjusted.

 Lower and upper alarm limit can be set to dependent 

    on set point.

 Temperature unit can be displayed in ° C or ° F.

 Digital input.

 Transfer device parameter settings with

    ENDAKEY-RF .

 RS485 communication features with Modbus RTU 

   protocol (optional).

 CE Marked according to European standards.

2

B

A

2

3

4

3

1

Panel cut-out

1)

 Panel thickness should

 

be maximum 7mm.

2)

 If there is no 60mm free

 

space at the back side of

 

the  device,

 

it  would  be

 

difficult to remove it from

 

the panel. 

1

To mounting device ;

 -

 Push the device in 

direction      .

 Note

 

:  

A

2

B -

 Push the clamps in the direction      . 

Remove the device from the panel by 
pulling in direction      .

A -

 Remove the side covers by lifting 

them with a flat screwdriver in direction 

To removing the device from panel :

2

3

4

DIMENSIONS

Specify at order.

Please see page 2 for Modbus 
Connection Diagram.

KEEP AWAY device from exposed to corrosive, volatile and flammable gases or liquids and 
DO NOT USE the device in similar hazardous locations.

Avoid any liquid contact while the device is switched on.
DO NOT clean the device with solvent (thinner, gasoline, acid etc.) and / or abrasive cleaning agents.

NO 250V AC, 8A,           1/2hp 240V AC

NO+NC 250V AC, 8A,    1/2hp 240V AC  

                                                     
                                          

NO 250V AC,8A ,            1/2hp 240V AC  

      EDT3423A-

EN

-01-

201214

ENDA

TM

Reviews: