TECHNICAL SPECIFICATIONS
Supply
230V AC +10
-20 , 50/60Hz or 24
%
%
V AC/DC 10%, 50/60Hz or 12V AC/DC 10%, 50/60Hz
±
±
Power consumption
Max 4VA
2.5mm² screw-terminal connections
±
1%
4 digits, 12.5mm, 7 segment yellow LED
Wiring
Scale
Sensitivity
Time Accuracy
Indicator
EMC
Safety requirements
EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B is satisfied for EMC tests.
The device is designed to operate in controlled electromagnetic environment)
EN 61010-1: 2001 (
)
pollution degree 2, overvoltage category II
START INPUT
Input type
Control with mechanical contact.
Min. = 100ms, Max. =
On and Off times for input pulses
OUTPUT
ELEKTRÝKSEL ÖZELLÝKLER
OUT
Relay: 250V AC, 8A (
), NO+NC
for resistive load
Mechanical 30.000.000 operation; Electrical 100.000 operation
Life expectancy for relay
ENVIRONMENTAL CONDITIONS
Height
2000m
Max.
80% up to 31°C decreasing linearly 50% at 40°C.
Ambient/storage temperature
Max. Relative humidity
0 ... +50°C/-25 ... +70°C (with no icing)
Selectable 99:59 min. or hour.
1 sec.
Rated pollution degree
According to EN 60529 Front panel : IP6
Rear panel : Ip20
5
Do not use the device in locations subject to corrosive and flammable gases.
HOUSING
Housing type
Suitable for flush-panel mounting
Dimensions
W77xH35xD71mm
Weight
Approx. 198g (after packing)
Enclosure material
Self extinguishing plastics
Thank you for choosing ENDA ETM1411 digital timer.
* 35 x 77mm sized.
* Single contact output for timing control.
* External start input.
* Display can be adjusted to show min. or sec.
* Scale ;
0:01 .... 99:59 mins.
0:01 .... 99:59 hrs.
* Decrease and increace step of time can be adjusted.
* Start and stop possibility by front panel.
* 16 different warning tones.
* Upper and lower limits of the setpoint can be
adjusted.
* CE marked according to European Norms.
Connection Diagram
ENDA ETM 411 is intended for installation in control panels. Make sure that the device is
used only for intended purpose. The shielding must be grounded on the instrument side.
During an installation, all of the cables that are connected to the device must be free of
electrical power. The device must be protected against inadmissible humidity, vibrations,
severe soiling and make sure that the operation temperature is not exceeded. All input and
output lines that are not connected to the supply network must be laid out as shielded and
twisted cables. These cables should not be close to the power cables or components. The
installation and electrical connections must be carried out by a qualified staff and must be
according to the relevant locally applicable regulations.
1
Panel cut-out
Dimensions
Note: 1) Panel thickness
should be maximum
7 mm.
2) If there is no 60mm
free space at the back
side of the device, it
would be difficult to
remove it from the panel.
Holding screw
0.4-0.5Nm
Equipment is protected throughout
by DOUBLE INSULATION.
34mm
70mm
8mm
85mm
71mm
29mm
Flush mounting
clamp
Flush mounting
clamp
Depth
Rubber
gasket
Panel
For removing mounting clamps:
Push out the flush-mounting
clamp in direction
as shown
in the figure below. Then, pull
out the clamp in direction
1
2.
2
1
While cleaning the device, solvents (thinner, benzine, acid etc.) or
must not be used.
corrosive materials
SN: XXXXXXXXX
1
2
3
4
5
6
7
8
9
10
11
12
ETM1411-230V
AC
DIGITAL
TIMER
START
ENDA
INDUSTRIALELECTRONICS
230V
AC +10% -20%
50/60Hz 4V
A
OUT
250V
AC 8A
RESISTIVE LOAD
7
8
SUPPLY:
NOTE :
184-253V AC
50/60Hz 4VA
Line
Neutral
230V AC
Supply
Switch
Note:
Cable size: 1,5mm²
Fuse
F 100 mA
250V AC
Fuse should
be connected.
1)
2)
Mains supply cords shall meet the requirements of
IEC 60227 or IEC 60245.
In accordance with the safety regulations, the power
supply switch shall bring the identification of
the relevant instrument and it should be easily accessible
by the operator.
ENDA ETM1411 DIGITAL TIMER
SET
START
STOP
ETM1411
DIGITAL TIMER
ENDA
OUT
MIN
HOUR
4
Please read this document carefully before using this product. The guarantee will be
invalidated if the device is damaged by not following instructions detailed in the
manual. The company shall not be responsible for any damage or losses however
caused, which may be experienced as a result of the installation or use of this product.
Order Code : ETM1411-
1
Supply Voltage
230VAC...230V AC
24............24V AC/DC
12............12V AC/DC
SET
START
STOP
ETM1411
DIGITAL TIMER
ENDA
OUT
HOUR
MIN
SN: XXXXXXXXX
1
2
3
4
5
6
7
8
9 10 11 12
ETM1411-230VAC
DIGITAL TIMER
START
ENDA
INDUSTRIAL ELECTRONICS
230V
AC +10% -20%
50/60Hz 4V
A
OUT
250V
AC 8A
RESISTIVE LOAD
START
SN: XXXXXXXXX
1
2
3
4
5
6
7
8
9 10 11 12
ETM1411-24
DIGITAL TIMER
ENDA
INDUSTRIAL ELECTRONICS
24V
AC/DC ±10%
50/60Hz 4V
A
OUT
250V
AC 8A
RESISTIVE LOAD
SURAN
Industrieelektronik
D-72160 Horb a.N.
Dettinger Str. 9
Tel.: +49 (0)7451 / 625 617
E-mail : info@suran-elektronik.de
Fax: +49 (0)7451 / 625 0650
Internet : www.suran-elektronik.de
1./2
ETM1411-E
uptodate:01022014,modificationreservedandcanbechangeanytimepreviousnotice!