TECHNICAL SPECIFICATIONS 

 

Supply

  230V AC +10  -20 , 50/60Hz or 24

%

%

V AC/DC  10%, 50/60Hz or 12V AC/DC  10%, 50/60Hz

±

±

 Power consumption

Max 4VA

2.5mm² screw-terminal connections

   

±

1% 

   4 digits, 12.5mm, 7 segment yellow LED

 

Wiring

 Scale
 Sensitivity
 Time Accuracy
 Indicator
 EMC

 

Safety requirements

 EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B is satisfied for EMC tests.
 The device is designed to operate in controlled electromagnetic environment) 

 EN 61010-1: 2001 (

)

pollution degree 2, overvoltage category II

START INPUT

 Input type

 Control with mechanical contact.
 Min. = 100ms  

On and Off times for input 
pulses

OUTPUT

ELEKTRÝKSEL ÖZELLÝKLER

 OUT 

 Relay: 250V AC, 8A (

), NO+NC

for resistive load

 Mechanical  30.000.000 operation; Electrical 100.000 operation

  

Life expectancy for relay

ENVIRONMENTAL CONDITIONS

 

Height

 

2000m

Max. 

80% up to 31°C decreasing linearly  50% at 40°C. 

 Ambient/storage temperature

 Max. Relative humidity

0 ... +50°C/-25 ... +70°C  (with no icing)  

Selectable 99:59 min. or hour.

1 sec.

Rated pollution degree

According to EN 60529                Front panel :    IP65
                                                       Rear panel  :    IP20

 Do not use the device in locations subject to corrosive and flammable gases.

HOUSING

 Housing type

 

Suitable for flush-panel mounting

 

Dimensions

 W77xH3

5

xD7

1

mm 

 

Weight

 Approx. 198g (after packing)

 Enclosure material

 

Self extinguishing plastics 

Thank you for choosing ENDA ETM1411 digital timer. 

* 3

5

 x 77mm sized. 

* Single contact output for timing control. 
* External start input. 
* Display can be adjusted to show min. or sec. 
* Scale ;
  0:01 .... 99:59 mins.
  0:01 .... 99:59 hrs. 
* Decrease and increace step of time can be adjusted. 
* Start and stop possibility by front panel. 
* 16 different warning tones. 
* Upper and lower limits of the setpoint can be 
   adjusted. 
* CE marked according to European Norms. 

Connection Diagram

ENDA ETM1411 is intended for installation in control panels. Make sure that the device is 
used only for intended purpose. The shielding must be grounded on the instrument side. 
During an installation, all of the cables that are connected to the device must be free of 
electrical power. The device must be protected against inadmissible humidity, vibrations, 
severe soiling and make sure that the operation temperature is not exceeded. All input and 
output lines that are not connected to the supply network must be laid out as shielded and 
twisted cables. These cables should not be close to the power cables or components. The 
installation and electrical connections must be carried out by a qualified staff and must be 
according to the relevant locally applicable regulations.  

1/2

SÝSEL MÜHENDÝSLÝK ELEKTRONÝK SAN. VE TÝC. A.Þ.
Yukarý Dudullu Barbaros Cad. Kutup Sok. No:20 34775 - ÜMRANÝYE/ÝSTANBUL/TÜRKÝYE
Tel : +90 216 499 46 64 Pbx.    Fax : +90 216 365 74 01
url : www.enda.com.tr

ETM

1

411-E-0

5-R

Holding screw
0.4-0.5Nm 

Equipment is protected throughout 
by DOUBLE INSULATION.

 While cleaning the device, solvents (thinner, benzine, acid etc.) or 

corrosive materials 

must not be used.

7

8

SUPPLY:

NOTE :

184-253V AC 
50/60Hz 4VA

Line

Neutral

230V AC
Supply

Switch

Note: 

Cable size: 1,5mm²

Fuse 

F 100 mA 

250V AC

Fuse should 
be connected.

1) 
    IEC 60227 or IEC 60245.
2) In accordance with the safety regulations, the power 
    supply switch shall bring the identification of 
    the relevant instrument and it should be easily accessible 
    by the operator.

Mains supply cords shall meet the requirements of  

ENDA

 

ETM

1

411 DIGITAL TIMER

Please read this document carefully before using this product. The guarantee will be 
invalidated if the device is damaged by not following instructions detailed in the
manual. The company shall not be responsible for any damage or losses however 
caused, which may be experienced as a result of the installation or use of this product.  

Order Code :

  

ETM

1

411-     

1

      Supply Voltage

      230VAC...230V AC
      24............24V AC/DC 
      12............12V AC/DC  

1-

2

4

V

 A

C

/D

C

 

1

0

%

 

5

0

/6

0

H

z

  

 4

V

A

±

SN: XXXXXXXXX

ETM14

11

-24

DIGITAL TIMER

ENDA

 

INDUSTRIAL ELECTRONICS

O

U

T

2

5

0

V

 A

C

 8

A

R

E

S

IS

T

IV

E

 L

O

A

D

1

2

3

4

5

6

7

8

9 10 11 12

START

SN: XXXXXXXXX

ETM14

11

-230VAC

DIGITAL TIMER

ENDA

 

INDUSTRIAL ELECTRONICS

2

3

0

V

 A

C

 +

1

0

%

 -

2

0

%

5

0

/6

0

H

z

  

4

V

A

O

U

T

2

5

0

V

 A

C

 8

A

R

E

S

IS

T

IV

E

 L

O

A

D

1

2

3

4

5

6

7

8

9 10 11 12

START

1

2

V

 A

C

/D

C

 

1

0

%

 

5

0

/6

0

H

z

  

 4

V

A

±

SN: XXXXXXXXX

ETM14

11

-12

DIGITAL TIMER

ENDA

 

INDUSTRIAL ELECTRONICS

O

U

T

2

5

0

V

 A

C

 8

A

R

E

S

IS

T

IV

E

 L

O

A

D

1

2

3

4

5

6

7

8

9 10 11 12

START

Panel cut-out

Dimensions

Note :  

1) Panel thickness 

    

should be maximum 

    

7 mm.

2)

 

If there is no 60mm 

    

free space at the back 

    

side of the device, it 

    

would be difficult to 

    

remove it from the 

    P

anel.

71mm

2

9

m

m

Flush mounting 

clamp

For removing mounting clamps:   

Push the flush-mounting 
clamp in

 

direction 

1

 as

 

shown 

in the figure below. Then, pull 
out the clamp in direction 

2. 

  

1

3

5

m

m

77mm

SET

SET

 ETM1411

ENDA

 

DIGITAL TIMER

 STOP

 START

 OUT  

 MIN  

 HOUR

SN

: X

XX

XX

XX

XX

ET

M1

4

11

-2

30

VA

C

DIG

IT

AL

 T

IM

ER

EN

DA

 

IN

DU

ST

RIA

L E

LE

CT

RO

NIC

S

2

3

0

V

 A

C

 +

1

0

%

 -2

0

%

5

0

/6

0

H

z

  4

V

A

O

U

T

2

5

0

V

 A

C

 8

A

R

E

S

IS

T

IV

E

 L

O

A

D

1

2

3

4

5

6

7

8

9

10

11

12

ST

AR

T

Flush mounting 

clamp

Depth

Panel

2

71mm

5mm

Rubber
packing

Reviews: