Endace Measurement Systems Limited
http://www.endace.com
EDM01.05-12r1 DAG 3.7T Card User Manual
Copyright, all rights reserved.
15
Version 6. 22 September 2005.
3.6 Inspect Interface Statistics
Description
Once the card has been configured as expected, the interface statistics
should be inspected to see if the interfaces are locked to the data stream.
dag@endace:~$ dagthree -d dag0 –si
if los ais lcv fls dmo clos - rx0 rx1 tx0 tx1 crc ais ferr up
0 0 0 0 0 0 0 - 1 1 1 1 0 0 0 1
1 0 0 0 0 0 0 - 1 1 1 1 0 0 0 1
2 0 0 0 0 0 0 - 1 1 1 1 0 0 0 1
3 0 0 0 0 0 0 - 1 1 1 1 0 0 0 1
4 0 0 0 0 0 0 - 1 1 1 1 0 0 0 1
5 0 0 0 0 0 0 - 1 1 1 1 0 0 0 1
6 0 0 0 0 0 0 - 1 1 1 1 0 0 0 1
7 0 0 0 0 0 0 - 1 1 1 1 0 0 0 1
8 0 0 0 0 0 0 - 1 1 1 1 0 0 0 1
9 0 0 0 0 0 0 - 1 1 1 1 0 0 0 1
10 0 0 0 0 0 0 - 1 1 1 1 0 0 0 1
11 0 0 0 0 0 0 - 1 1 1 1 0 0 0 1
12 0 0 0 0 0 0 - 1 1 1 1 0 0 0 1
13 0 0 0 0 0 0 - 1 1 1 1 0 0 0 1
14 0 0 0 0 0 0 - 1 1 1 1 0 0 0 1
15 0 0 0 0 0 0 - 1 1 1 1 0 0 0 1
Status bits
display
The tool will display a number of status bits as they have occurred since
the last time read. In our example, the interval is set to one second via the
-
i
option.
if
Number (0-15)
los
LIU Loss of signal
ais
LIU Alarm Indication Signal
lcv
LIU Line code violation
fls
LIU FIFO limit status
dmo
LIU Drive monitor output
clos
LIU Cable loss (dB +/- 1dB)
rx0
Framer ever received 0
rx1
Framer ever received 1
tx0
Framer ever sent 0
tx1
Framer ever sent 1
crc
Framer CRC error
ais
Framer Alarm Indication Signal
ferr
Framer error
up
Framer up