Endace Measurement Systems Limited
http://www.endace.com
EDM01.05-12r1 DAG 3.7T Card User Manual
Copyright, all rights reserved.
23
Version 6. 22 September 2005.
3.9.4 Hyper-channel Connection ['h']
Description
A hyper-channel connection is a connection which occupies 1 or more
timeslots on 1 interface. This line would look like:
h bit_offset ifc_num ts_num ts_num ts_num ...
The
bit_offset
field is always
0
. There has been no use for this at the
present time. In order to configure a connection on interface 3, timeslots
0, 1, 2, 26, 27, 28, 29 it would look like:
h
0
3
0
1
2
26
27
28
29
3.9.5 Line Connection ['l']
Description
A line connection is a connection which occupies all timeslots, for
example full line rate, on 1 interface, but is not in RAW mode. This line
would look like this:
l bit_offset ifc_num
The
bit_offset
field is always
0
. There has been no use for this at the
present time. In order to configure a line connection on interface
0
it
would look like:
l 0 0
3.9.6 Sub-channel Connection ['s']
Description
A sub-channel connection is an ATM connection which occupies 1, 2, or 4
conectutive bits within a timeslot on one interface. The line would look
like this:
s bit_offset ifc_num ts_num ts_mask
The
bit_offset
field is always 0. So far, we have no use for it. In order
to configure a connection on interface 6, timeslot 2, bits 0-3 would look
like this:
s
0
6
2
0
0
0
0
1
1
1
1
Continued on next page