Endace Measurement Systems Limited
http://www.endace.com
EDM01.05-12r1 DAG 3.7T Card User Manual
Copyright, all rights reserved.
17
Version 6. 22 September 2005.
3.7.1 Configuring DAG 3.7T Card for Receive and Transmit
Description
Ensure the DAG 3.7T card has the appropriate transmit firmware image
loaded.
The DAG 3.7T does not support HDLC transmit in this release.
3.7.2 Timeslot Connection ['c']
Description
A timeslot connection is a connection which occupies only one timeslot
on one interface at 64 kbps. The line would look like:
c bit_offset ifc_num ts_num
The
bit_offset
field is always
0
, it is reserved for future use.
In order to configure a connection on interface 5, timeslot 16 it would look
like:
c
0 5
16
0 5
16
3.7.3 Delete Connection ['d']
Description
In order to delete a connection, the connection must already exist. This is
used with
dagchan
. When
is started there are no connections, so
all connections to be created and deleted must exist in the .
cfg
file. This
line would look like:
d conn_num
To delete connection number 17:
d 17
3.7.4 Hyper-channel Connection ['h']
Description
A hyper-channel connection is a connection which occupies 1 or more
timeslots on 1 interface. This line would look like:
h bit_offset ifc_num ts_num ts_num ts_num ...
The
bit_offset
field is always
0
. There has been no use for this at the
present time. In order to configure a connection on interface 3, timeslots
0, 1, 2, 26, 27, 28, 29 it would look like:
h
0
3
0
1
2
26
27
28
29