EDM05-01v6 Time Distribution Server User Guide - Appendix A: TDS2 Module Connector Specifications
©2011 Endace Technology Ltd. Confidential - Version 6 - November 2011
13
Appendix A: TDS2 Module Connector Specifications
RS422 RJ45 Timing Signal Output
The TDS2 Server Module has two RJ45 socket outputs for connecting to a DAG card RS422 synchronization input
port. The socket consists of 8 pins.
The pin-out configuration is shown below:
1 NC
2 NC
3 PPS
Out+
4 SERIAL
Out+
5 SERIAL
Out-
6 PPS
Out-
7 NC
8 NC
RS232 DB9 CDMA Input
The TDS2 Server Module has one male DB9 input for connecting the Endrun Technologies Praecis Ct CDMA time
receiver using standard Ethernet cables.
The pin-out configuration is shown:
1 PPS
In
2 SERIAL
In
3 Ext-SERIAL
Out
4 NC
5 Ground
6 NC
7 CTS Out
8 NC
9 NC
Note:
The "In" and "Out" destinations relate to TDS2 Modules and TDS6 Units.
RS422 DB9 GPS Input
The TDS2 Server Module has one female DB9 input for connecting the Trimble Acutime GPS Receiver.
The pin-out configuration is shown below:
1
Event Out+ (optional)
2
Event Out- (optional)
3 PPS
In+
4 SERIAL
In+
5 SERIAL
In-
6 PPS
In-
7 N/C
8 Ground
9
Power Out (12VDC)