ENDEAVOUR Int. Ltd. Tel +44 (0) 1225 446770 Fax +44 (0) 1225 446775
25
Long press Jog wheel to go to Main Menu at any time
www.endeavourinternational.ltd.uk
You will be prompted to confirm that you want to calibrate the machine. Do this by rotating the
jog wheel to “YES” and pressing it to confirm:
You will be prompted to fit the dies required for the calibration mandrel size, manually:
or using the quick change tool of available:
Once the dies are fitted, you will be prompted to use the large mandrel:
Place the large diameter of the calibration mandrel into the swaging head and press the green
button to close the jaws onto the mandrel.
MAINTAIN THE GREEN BUTTON PRESSED UNTIL THE MACHINE FULLY CLOSES
ONTO THE MANDREL AND THE NUMBER ON THE DISPLAY DOES NOT INCREASE,
THEN PRESS THE JOG WHEEL TO ACCEPT.
Large Mandrel
OK(↓)
350
Large Mandrel
OK(↓)
0
H26
Fit Die H26
Q/C(Grn) OK(↓)
H26
Fit Die
H26
Manual OK(↓)
Calibrate?
Yes
Calibrate?
No
Setup Menu
Calibrate
Main Menu
Setup Menu