Fastlane
®
Pro Swim Unit Installation
Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal
body temperature of 98.6 °F (37 °C). The symptoms of hyperthermia include drowsiness, lethargy, and an increase
in the internal temperature of the body. The effects of hyperthermia include. L'hyperthermie se produit lorsque la
température interne du corps atteint un niveau supérieur de plusieurs degrés à la température corporelle normale de
37 °C (98.6 °F). Les symptômes de l'hyperthermie comprennent la somnolence, la léthargie et une augmentation de
la température interne du corps. Les effets de l'hyperthermie comprennent.
a) unawareness of impending hazard/ méconnaissance d'un danger imminent.
b) failure to perceive heat/ incapacité à percevoir la chaleur.
c) failure to recognize the need to exit spa/ incapacité à reconnaître la nécessité de quitter le spa.
d) physical inability to exit spa/ incapacité physique de quitter le spa.
e) fetal damage in pregnant women/ dommages foetaux chez les femmes enceintes.
f) unconsciousness and danger of drowning/ inconscience et danger de noyade.
Suction Outlet Fitting Safety Instructions
When installing and using this equipment, basic safety precautions shall always be followed including the following
IMPORTANT SAFETY INSTRUCTIONS.
WARNING:
Any modification that increases the flow rate of the circulation system shall require re-evaluation of
the cover/grate and sump to ensure that the flow rating of the suction outlet fitting is not exceeded.
WARNING:
Missing, broken, or cracked cover/grates, sumps, mud frames, or any other suction outlet fitting com-
ponent shall be replaced before bathers are allowed to use the unit.
WARNING:
Loose cover/grates shall be reattached before bathers are allowed to use the unit.
Suction Outlet Fitting User Maintenance Instructions
Field Modifications:
Any field modification made to the suction outlet fitting not authorized by Endless Pools installation instructions shall
void the suction outlet fitting assembly certification.
Configuration Modifications:
No modification shall be made to a suction outlet fitting structure or flow path unless the new configuration has been
certified as a new suction outlet fitting assembly.
Service Life:
The suction outlet fitting is constructed of 316L perforated stainless steel. It shall be replaced after 25 years of use
using a #2 Phillips head screwdriver. The suction outlet fitting shall be replaced at or before the end of the service
life. The service life of the suction outlet fitting begins the month and year in which the suction outlet fitting is in-
stalled with or without water.
Service Instructions:
If service is required to inspect, repair, or replace the suction outlet fitting, it shall be done so with a #2 Phillips
head screwdriver. DO NOT USE POWER TOOLS TO INSTALL FASTENERS. Start installation of screws by hand to
ensure proper thread engagement and to prevent cross threading. REFER TO “SUCTION OUTLET FITTING SERVICE
INSTRUCTIONS” FOR ANY SERVICE REQUIRED TO REPAIR OR REPLACE ANY SUCTION OUTLET FITTING COM-
PONENT OR FASTENER.
1. Hand check the suction outlet fitting after installation to verify that it’s snug.
2. Before each use, verify the suction outlet fitting including the fasteners, are
undamaged and have not been tampered with.
3. Any missing, broken, or cracked suction outlet fitting shall be replaced before using.
4. A loose suction outlet fitting and associated components shall be reattached before using.
5. The suction outlet fitting components and fastener receptacles shall be clean and free of debris or
obstructions during the installation.
SAVE THESE INSTRUCTIONS. CONSERVEZ CES INSTRUCTIONS.
5