Page 5
e
lectrIcal
r
equIrementS
IMPORTANT:
Fill the
RECSPORT
Recreation System with water
before turning on the power.
Your
ENDLESS POOLS RECSPORT
Recreation System has been
carefully designed to give you maximum safety against electrical shock.
Connecting the
RECSPORT
Recreation System to an improperly wired
circuit will negate many of the
RECSPORT
Recreation System’s safety
features. Improper wiring may also cause electrocution, risk of fire, and
other risks of injuries. Please read and follow the electrical installation
requirements and instructions completely!
230 VOLT PERMANENTLY
CONNECTED
ENDLESS POOLS RECSPORT
Recreation Systems must be wired
in accordance with all applicable local electrical codes. All electrical
work should be done by an experienced, licensed electrician. We
recommend the use of appropriate electrical conduit, fittings, and wire
for all circuits.
The diagram below illustrates how to wire the RECSPORT
Recreation System model:
• An electrical subpanel containing a 30 Amp breaker is included with
your
RECSPORT
Recreation System. We recommend that this
subpanel be used to supply power to the
RECSPORT
Recreation
System.
• The subpanel requires a 30 amp, single phase, 230 volt, four
wire service (two line, one neutral, one ground). The grounding
conductor must not be less than #8 AWG. Refer to local codes and
to NEC 250-122 (table).
• Mount the subpanel in the vicinity of the
RECSPORT
Recreation
System, but not closer than five feet away, in accordance with all
local codes. (N.E.C. 680-38 to 41-A-3)
• Open
RECSPORT
Recreation System by removing the 4 screws
holding the vertical T-spacer located in the center of the equipment
compartment (back side of
RECSPORT
Recreation System). Slide
panel towards center and remove, repeat for other panel.
• Insert power wires into
RECSPORT
Recreation System from either
side towards the bottom, you will find a plastic cap attached to wall.
• Once your
RECSPORT
Recreation System has been filled with
water, turn it on and test all of the circuit breakers.
IMPORTANT:
If breaker immediately trips, verify that the wires are
correctly connected. Breaker should be tested prior to each use. Here’s
how:
1. Push the “TEST” button on each GFCI breaker, and observe it
click OFF.
2. Wait 30 seconds, then push the breaker switch to the OFF (down)
position (to ensure that it has completely disengaged), then push
the breaker switch to the ON (up) position. If you don't wait 30
seconds, the
RECSPORT
Recreation System’s power indicator
may continue to blink – try again.
If the GFCI breakers fails to operate in this manner, your
RECSPORT
Recreation System may have an electrical malfunction, and you may
be at risk of electrical shock. Turn off all circuits and do not use the
RECSPORT
Recreation System until the problem has been corrected
by an authorized service agent.
WARNING:
Removing, or bypassing any GFCI breaker will result
in an unsafe
RECSPORT
Recreation System and will void the
RECSPORT
Recreation System’s warranty.
IMPORTANT
: If you ever need to move or relocate your
ENDLESS POOLS RECSPORT
Recreation System, it is essential that you understand and
apply these installation requirements. Your
ENDLESS POOLS RECSPORT
Recreation System has been carefully engineered to provide maximum
safety against electric shock. Remember, connecting the
RECSPORT
Recreation System to an improperly wired circuit will negate many of its safety
features.
NOTE
: Long wiring runs may require larger-gauge wire than stated.
Electrical Requirements
L1
N
G
L2
N
L2
L3
L1
G
230 VAC, 30A, 60Hz, ALL MODELS
#8
#8
#8
#8
#8
#10
#10
#10