Magical balancer
5
Usage of Magical Balancer
33
5-8
Setting No-Load Weight using select switch (Option)
The magical balancer allows you to set the no-load weight for each attachment
It can be set as a no-load state.
WARNING
Do not perform any operations other than setting the no-load weight in "Calibration
Mode".
This may change the control parameters of the magical balancer and cause
operational errors.
NOTE
Saving the current operating parameters will overwrite the shipping operating parameters and
will not allow the user to return to the shipping operating parameters.
To set the no-load weight for each attachment, hold the attachment or jig that you want to set to
no-load weight.
Operation
Control panel
LCD display screen
1.
Operate the grip of the magical balancer to lift the jig and stop it in the
middle.
2.
Switch the select switch to right side.
The right side is for jigs and the left side is for standard
hooks.
3.
Press the [Mode] key until "Calibration Mode" is displayed.
1.
After pressing the [Shift] key at least twice, press the [Set] ke
y while holding down the [Shift] key.
2.
Press the [Set] key again until the screen shown on the right
appears.
3.
Press the [
△
] key ([
▼
] key) to select the attachment whose
parameters are to be changed.
Attach1. Standard lower hook (when jig is not used)
Attach2. Magical balancer-interlocked vacuum jig
Attach3. Magical balancer interlocking clamp jig
Attach4. Jig without interlocking control with magical balancer
1.
When the [Set] key is pressed, the screen shown on the righ
t is displayed and the no-load weight is recalculated.
(The figure on the right is when Attach1 is selected.
Do not touch the grip controller during recalculation.
2.
After recalculating the no-load weight, the screen shown on th
e right will be displayed.
3.
Press the [Mode] key three times to exit the "Calibration Mod
e".
Calibration Mode
Calibration Mode
No Load MEASURE
No Load Wt. Set
Attach1 Measure?
Attach1 Weight
Measuring Wait!
Attach1 Weight
Completed !
Calibration Mode