Magical balancer
6
Periodic Inspections and Maintenance
35
Monthly inspection
Perform an inspection at least once per month and take appropriate measures against abnormal
parts.
Since the number of inspections varies with the operating environment, the frequency of use,
and the weight condition of the Magical Balancer, shorten the inspection intervals according
to the operating conditions.
For the inspection items and methods, refer to “6-2 Inspection”.
Operating limit of the parts
It is very dangerous to use the parts that are worn beyond the standard during the inspections and
other checks.
Never use such parts.
6-1
Lubrication
6-1-1 Lubrication for the main equipment of the Magical Balancer
When disassembling the equipment, use the lubricating oils in the table or their equivalents
recommended by the manufacturers for the following sections.
Manufacturer
Casing and piston section
Ball screw and thrust bearing
Exxon Mobil Corporation Mobilux EP 1
Mobilux EP 2
Kyodo Yushi Co., Ltd.
One Luber MP 1
One Luber MP 2
Cosmo Oil Co., Ltd.
Cosmo Grease Dynamax No. 1 Cosmo Grease Dynamax No. 2
Showa Shell Sekiyu K.K. Alvania EP Grease 1
Alvania EP Grease 2
CAUTION
Do not use any type of lubricating oil for the control module.
Sophisticated parts are used on the air pipeline of the control module. Therefore,
do not install a lubricator (oiler) on the air supply line of the Magical Balancer
because it may cause a malfunction of valves or damage to the internal parts.