The Light pack contains: 

Wall light and bracket. 

Terminal connection block. 

GU10 lamps 

 

The following tools may be required: 

Selection of cross and flat head screwdrivers. 

Electric drill and assorted drill bits. 

Wire strippers. 

Electrical insulation tape. 

 

 

 

 

INSTRUCTION MANUAL

 

 

 

These products are only suitable for connection to a 240V~50Hz supply.   

 

It is recommended that these lights are installed by a qualified electrician in accordance with current IEE 

Wiring Regulations and Building Regulations (Part P).  

These fittings should be connected to a lighting circuit protected by a 5 amp fuse (or a 6 amp miniature circuit 

breaker). 

 

These lights have an IP44 (splash proof) rating suitable for use outdoors. 

 

Run supply wire from a 5-amp electrical supply using double insulated 3-core cable of type H05RN-F 1.0mm

2

  

(not supplied) to selected site, ensuring it is adequately protected through the full length of the cable run, it  

must come out of the flat surface of the mounting surface in line with the entry to the fitting. 

 

Except where installed in a conduit or duct , which provides equivalent protection against mechanical damage, 

a cable buried in the ground shall incorporate an earthed armour or metal sheath or both, suitable for use as a 

protective conductor, or be of insulated concentric construction. Buried cables shall be marked by cable 

covers or a suitable marking tape. Buried conduits and ducts shall be suitably identified. Buried cables, 

conduits and ducts shall be at a sufficient depth to avoid being damaged by any reasonably foreseeable 

disturbance of the ground. 

 

These products contain breakable parts – be careful during handling and maintenance to avoid breakage. 

 

The shades can become hot in use. Switch off and allow 10 minutes to cool before cleaning (using a dry cloth 

only – do not use liquid or abrasive cleaners). 

 

If the covers are broken or cracked then they must be replaced immediately to preserve the water ingress 

protection, please consult your retailer. This is represented by the symbol  

 

 

IMPORTANT: To achieve maximum corrosion resistance the surface of the Stainless Steel must be kept clean. 

Surface contamination and the formation of deposits are critical factors which may lead to drastically reduced 

life. An example is salt deposits from marine conditions. Cleaning with soap or a mild detergent and warm 

water followed by a careful clean water rinse and finally wiping dry is usually adequate for most S/S items 

used in the domestic environment. Care must be taken to turn off the mains supply until the cleaning process 

has been completed and the fitting is completely dry.

 

 

If any modification is made it will invalidate the warranty and may render the product unsafe. 

 

Before you start 

Please read these instructions carefully before fitting your new light and retain for reference. 

Switch off the mains supply and remove the appropriate fuse or switch off the appropriate circuit breaker 

before commencing installation. 

Ensure that no one else has access that would enable the supply to be inadvertently reconnected. 

Check the packaging and make sure that you have all the required parts.  

Follow each assembly step in order to prevent incorrect assembly 

Make sure all screws / nuts, including electrical connections etc are fully tightened before use. 

This type of Light Fitting may be connected to a Dimmer if a Tungsten incandescent bulb is used (as 

supplied). If a CFL type bulb is fitted then these cannot (generally) be controlled by a dimmer.

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EL- 40094 / EL- 40095 – Single / Twin Outdoor wall fittings. 

Safety Warnings 