background image

 

The Light pack contains: 

PIR Wall light with non-replaceable led`s. 

PIR Specifications (all values are approximate). 

Working Temperature:  -20°C / +50°C. 
Voltage: 180VAC – 250VAC 50-60Hz. 
Load: Max 60w Incandescent. 
Detection distance: 0 – 12m. 
Detection angle: 130°. 
Time on: 10 seconds. 
Lux level: < 30lux / >70lux 
 

The following tools may be required: 

Selection of cross and flat head screwdrivers. 
Electric drill and assorted drill bits. 
Wire strippers. 
Electrical insulation tape. 

 

 

 

 

INSTRUCTION MANUAL

 

 

 

This product is only suitable for connection to a 240V~50Hz supply.   
 
It is recommended that this light is installed by a qualified electrician in accordance with current IEE Wiring 
Regulations and local Building Regulations.  
The light fitting should be connected to a lighting circuit protected by a 5 amp fuse (or a 6 amp miniature 
circuit breaker). 
 
This light has an IP44 (splash proof) rating suitable for use outdoors. 
 
Run supply wire from a 5-amp electrical supply using double insulated 3-core cable of type H05RN-F 1.0mm

2

  

(not supplied) to selected site, ensuring it is adequately protected through the full length of the cable run, it  
must come out of the flat surface of the mounting surface in line with the entry to the fitting. 
 
Except where installed in a conduit or duct , which provides equivalent protection against mechanical damage, 
a cable buried in the ground shall incorporate an earthed armour or metal sheath or both, suitable for use as a 
protective conductor, or be of insulated concentric construction. Buried cables shall be marked by cable 
covers or a suitable marking tape. Buried conduits and ducts shall be suitably identified. Buried cables, 
conduits and ducts shall be at a sufficient depth to avoid being damaged by any reasonably foreseeable 
disturbance of the ground. 
 
This product contains breakable parts – be careful during handling and maintenance to avoid breakage. 
 
This fitting uses none-replaceable LED`s.  We recommend that you do not stare directly into the light beam. 
 
The diffuser (cover) can become hot in use. Switch off and allow 10 minutes to cool before cleaning (using a 
dry cloth only – do not use liquid or abrasive cleaners). 
 
If the cover is broken or cracked then it cannot be replaced and the fittings must not be used - as the water 
ingress protection has been compromised.  
 
Clean using a dry cloth only – do not use liquid or abrasive cleaners. 
 
If any modification is made it will invalidate the warranty and may render the product unsafe. 

 
 

Before you start 

Please read these instructions carefully before fitting your new light and retain for reference. 
Switch off the mains supply and remove the appropriate fuse or switch off the appropriate circuit breaker 
before commencing installation. 
Ensure that no one else has access that would enable the supply to be inadvertently reconnected. 

Check the packaging and make sure that you have all the required parts.  
Follow each assembly step in order to prevent incorrect assembly 
Make sure all screws / nuts, including electrical connections etc are fully tightened before use. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 

EL- 40113 -  LED PIR Outdoor wall fitting. 

Safety Warnings 

Reviews: