Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory
operation of this product. Please retain these instructions for future reference.
Warning
This light fitting is double insulated (class 2) and
does not require connection to an Earth circuit
Please read these instructions carefully before
commencing any work.
This unit must be fitted by a competent and qualified
electrician.
Install in accordance with IEE Wiring regulations and
current Building Regulations.
To prevent electrocution switch off at mains supply
before installing or maintaining this fitting. Ensure other
persons cannot restore the electrical supply without your
knowledge.
This light fitting should be connected to a fused circuit.
If replacing an existing fitting, make a careful note of the
connections.
Always use the correct type and wattage bulb. Never
exceed the wattage stated.
When changing a bulb, always switch off at the mains and
allow the old bulb to cool down before handling.
Dispose of used bulbs carefully and responsibly.
This product is suitable for dimming when used in
conjunction with a dimmable lamp. Please ensure
verification of dimming abilities with the lamp
manufacture prior to use.
Waste electrical products should not be disposed of with
household waste. Please recycle where facilities exist.
Check with your local authority or retailer for recycling
advice.
Specification
Voltage:
240V 50Hz a.c.
Lamp:
1 x 35W GU10 Halogen
IP rating:
44
Layout
Existing fittings must be completely removed before
installation of a new product. Before removing the existing
fitting,
carefully note the position of each set of wires
.
• Undo the screws holding the fixing bracket
in place and set aside
• Hold the product in place and mark the position of the
holes.
• Ensure the ceiling is capable of holding the weight of
the product. Take care to avoid damaging any concealed
wiring and pipes.The correct fixings should be used.
Ensure there is a joist at the point of fixing to support the
weight of the product.
• Fix the ceiling bracket into position.
Installation
Wiring
Having correctly identified the wiring from your existing light
fitting, pull the wire through the hole and connect to the
connection block inside the product in the following way:
This unit is double insulated and must not be earthed. If
there are any incoming earth cables, they must be joined
together and well insulated with good quality insulation tape.
This is to ensure earth continuity throughout your property.
Check that...
• You have correctly identified the wires
• The connections are tight
• No loose strands have been left out of the connection
block.
0.2m
OUTSIDE ZONES
ZONE
2
ZONE
1
0.6m
0.6m
2.25m
Ceiling
Spotlights give a concentrated beam
of light and must not be positioned
any closer than 0.2M (20cm) to the
illuminated surface.
This product is suitable for use in Zone
2 and outside Zones of a bathroom.
See diagram. If this unit is being
fitted in a room containing a bath or
shower, a 30mA RCD must be used, in
accordance with IEE regulations.
• Plan the desired layout of this fitting carefully, ensuring
the cables will reach the distance between the junction
box and the light fitting
• Avoid locating any cables in positions that would cause
a hazard. Position cables and junction boxes (not
supplied) away from areas where they may be at risk
from being cut, trapped or damaged
• The mains supply cable must have a minimum cross
sectional area of 1.0mm²
• This product must be mounted out of arms reach.
• This product has special protection against the ingress
of moisture and is IP44 rated.