Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory 
operation of this product. Please retain these instructions for future reference.

Warning

This light fitting is double insulated (class 2) and 
does not require connection to an Earth circuit

Please read these instructions carefully before 
commencing any work. 

This unit must be fitted by a competent and qualified 
electrician.

Install in accordance with IEE Wiring regulations and 
current Building Regulations.

To prevent electrocution switch off at mains supply 
before installing or maintaining this fitting. Ensure other 
persons cannot  restore the electrical supply without your 
knowledge.

This light fitting should be connected to a fused circuit.

If replacing an existing fitting, make a careful note of the 
connections.

Always use the correct type and wattage bulb.  Never 
exceed the wattage stated.

When changing a bulb, always switch off at the mains and 
allow the old bulb to cool down before handling.  
Dispose of used bulbs carefully and responsibly.
This product is suitable for dimming when used in 
conjunction with a dimmable lamp. Please ensure 
verification of dimming abilities with the lamp 
manufacture prior to use.

Waste electrical products should not be disposed of with 
household waste. Please recycle where facilities exist. 
Check with your local authority or retailer for recycling 
advice.

Specification

Voltage: 

240V 50Hz a.c.

Lamp: 

1 x 35W GU10 Halogen

IP rating: 

44

Layout

Existing fittings must be completely removed before 
installation of a new product. Before removing the existing 
fitting, 

carefully note the position of each set of wires

.

•  Undo the screws holding the fixing bracket

  in place and set aside

•  Hold the product in place and mark the position of the 

holes.

•  Ensure the ceiling is capable of holding the weight of 

the product. Take care to avoid damaging any concealed 
wiring and pipes.The correct fixings should be used. 
Ensure there is a joist at the point of fixing to support the 
weight of the product. 

•  Fix the ceiling bracket into position.

Installation

Wiring

Having correctly identified the wiring from your existing light 
fitting, pull the wire through the hole and connect to the 
connection block inside the product in the following way:
This unit is double insulated and must not be earthed. If 
there are any incoming earth cables, they must be joined 

together and well insulated with good quality insulation tape. 
This is to ensure earth continuity throughout your property.

Check that...

•  You have correctly identified the wires
•  The connections are tight

•  No loose strands have been left out of the connection 

block.

0.2m

OUTSIDE ZONES

ZONE

2

ZONE

1

0.6m

0.6m

2.25m

Ceiling

Spotlights give a concentrated beam 
of light and must not be positioned 
any closer than 0.2M (20cm) to the 
illuminated surface.

This product is suitable for use in Zone 
2 and outside Zones of a bathroom. 
See diagram. If this unit is being 
fitted in a room containing a bath or 
shower, a 30mA RCD must be used, in 
accordance with IEE regulations.

•  Plan the desired layout of this fitting carefully, ensuring 

the cables will reach the distance between the junction 
box and the light fitting

•  Avoid locating any cables in positions that would cause 

a hazard. Position cables and junction boxes (not 
supplied) away from areas where they may be at risk 
from being cut, trapped or damaged

•  The mains supply cable must have a minimum cross 

sectional area of 1.0mm²

•  This product must be mounted out of arms reach.

•  This product has special protection against the ingress 

of moisture and is IP44 rated.