background image

 

 

These assembly diagrams are intended as a guide – if in doubt consult a qualified electrician.

  

NOTE – The uplight unit YG-862-SS CANNOT be used as a downlight and the downlighter – YG-861-

SS CANNOT  be used as an uplight. This is because of the position on the drain holes in the two 

construction.  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

Assembly / user instructions 

Endon Lighting 

LS9 0SE 

 

20150807 

N210 117 

Diagram A 

Diagram B 

Diagram C 

1.    Determine the position of your light 

fitting taking into account the exit 
position of the cable. Ensure that the 
mounting surface is solid, preferably 
a brick or block wall and ensure that 
there are no other cables or pipes 
beneath the surface. Use 
appropriate fixings. Wall plugs and 
screws as supplied are shown here.  

 

2. 

    

Diagram A

Separate the plastic 

back plate from the fitting by 
removing the two domed nuts / 
washers (1) on the front of the 
fitting. Leave the threaded (2) bolts 
in the back plate.  

 

3.    Diagram B

. The internal terminal 

block (3) can be removed from its 
mounting position inside the back 
plate to ease fitment of the back 
plate. Use the back plate as a 
template to mark the screw holes. 

Make sure the back plate is 

correctly aligned with the drain 

hole (4) at the lowest position.  

 

4. 

   

Use a sharp object such as a 
screwdriver to pierce the rubber 
grommet in the back plate. Feed the 
incoming cable (5) through the 
rubber grommet and attach the back 
plate to the wall. Do not over tighten 
as this could damage the back plate. 
 

5. 

   Connect the house wiring to the 

internal terminal block (3). 

NOTE:

 

This is a Class I fitting and

 

must 

be earthed.  

             See wiring details.

 

 

6.    Diagram C. 

Place the fitting over 

the back plate, ensuring that the 
bolts in the back plate are aligned 
with the holes in the front of the 
fitting. Replace the domed nuts / 
washers to secure the fitting. Fit the 
bulb (6) (not supplied) into the lamp 
holder. 

NOTE:

 

Never fit bulbs of a 

higher wattage or of a type other 

than those specified on the label 

(as these may cause overheating 

and damage the fitting).  

 

7. 

   Fit the cage (7) and cover (8) 

together with the 3 x securing 
screws. 

 

 

8.   Turn on the power and test. 

 

 

 
 
 
 

Uplighter 

Downlighter 

Reviews: