background image

 

The Light pack contains: 

IP44 rated Floor standing lights. 
 

The following tools may be required: 

Selection of cross and flat head screwdrivers. 
Electric drill and assorted drill bits. 
Wire strippers. 
Electrical insulation tape. 

 

 

 

 

INSTRUCTION MANUAL

 

 

 

These products are only suitable for connection to a 240V~50Hz supply.   

 

It is recommended that these floor standing lights are installed by a qualified electrician in accordance with 

current IEE Wiring Regulations and local Building Regulations and are for the Domestic environment only.  

 

These light fittings should be connected to a lighting circuit protected by a 5 amp fuse (or a 6 amp miniature 

circuit breaker). 

 

These lights have an IP44 (splash proof) rating suitable for use outdoors. 

 

Run supply wire from a 5-amp electrical supply using double insulated 3-core cable of type H05RN-F 1.0mm

2

  

(not supplied) to selected site, ensuring it is adequately protected through the full length of the cable run, it  

must come out of the mounting surface in line with the entry to the fitting and should be long enough to  

enable it to be connected to the terminal block under the lantern head. 

 

Except where installed in a conduit or duct , which provides equivalent protection against mechanical damage, 

a cable buried in the ground shall incorporate an earthed armour or metal sheath or both, suitable for use as a 

protective conductor, or be of insulated concentric construction. Buried cables shall be marked by cable 

covers or a suitable marking tape. Buried conduits and ducts shall be suitably identified. Buried cables, 

conduits and ducts shall be at a sufficient depth to avoid being damaged by any reasonably foreseeable 

disturbance of the ground. 

 

These product contain breakable parts – be careful during handling and maintenance to avoid breakage. 

 

If the cover is broken or cracked then it must be replaced immediately to preserve the water ingress 

protection, please consult your retailer. This is represented by the symbol  

 

 

 

IMPORTANT: To achieve maximum corrosion resistance the surface of the Stainless Steel must be kept clean. 

Surface contamination and the formation of deposits are critical factors which may lead to drastically reduced 

life. An example is salt deposits from marine conditions. Cleaning with soap or a mild detergent and warm 

water followed by a careful clean water rinse and finally wiping dry is usually adequate for most S/S items 

used in the domestic environment. Care must be taken to turn off the mains supply until the cleaning process 

has been completed and the fitting is completely dry.

 

 

If any modification is made it will invalidate the warranty and may render the products unsafe. 

Before you start 

Please read these instructions carefully before fitting your new light and retain for reference. 

Switch off the mains supply and remove the appropriate fuse or switch off the appropriate circuit breaker 

before commencing installation. 

Ensure that no one else has access that would enable the supply to be inadvertently reconnected. 

Ensure that there are no cables / pipes beneath the surface (other than the supply cable for this fitting). 

The mounting surface must be secure and able to accommodate the weight / height of the fitting. If installing on an 
existing secure (concrete) base, use the holes in the lamp post base as a template to drill suitable fixing holes and 
prepare with suitable ground fixing bolts (not supplied).The supply cable must be long enough to come out of the 
mounting surface and directly into the terminal block under the lamp head. 

MAKE

 sure the cable length that is required 

is accurately determined before assembly.

 

Check the packaging and make sure that you have all the required parts.  
Follow each assembly step in order to prevent incorrect assembly 
Make sure all screws / nuts, including electrical connections etc are fully tightened before use. 

 

 

 

 

 

 

 

 

 

 

 

 

YG-863-SS / YG-864-SS -  Outdoor floor mounted fittings. 

Safety Warnings 

Reviews: